General Specifi cations
Title
Specifi cation
Dimension
U1211A
106 mm (W) X 273 mm (L) X 43 mm (H)
106 mm (W) X 273 mm (L) X 43 mm (H)
U1212A & U1213A
106 mm (W) X 260 mm (L) X 43 mm (H)
106 mm (W) X 260 mm (L) X 43 mm (H)
Net Weight
U1211A
625 grams with batteries included
625 grams with batteries included
U1212A & U1213A
525 grams with batteries included
525 grams with batteries included
Display
4 digits with maximum reading 4,100 counts. The 12 Segments analog bar graph
and full annunciator. Automatic polarity indication.
and full annunciator. Automatic polarity indication.
Battery
Standard 9 V Battery - Alkaline
Low batt indicator
Battery voltage drops below 6.0 V
Power Consumption
U1211A
186 mVA maximum
186 mVA maximum
U1212A & U1213A
220 mVA maximum
220 mVA maximum
Battery life
60 hours (typical)
Maximum jaw opening
~2 inches
Temperature coeffi cient
0.12 x (specifi ed accuracy) / °C (from 0 °C to 18 °C or 28 °C to 50 °C)
NMRR (Normal Mode Rejection
Ratio)
Ratio)
This series has a NMRR specifi cation of > 60 dB at 50 Hz and 60 Hz, which means
a good ability to reject the effect of AC noise in DC measurement
a good ability to reject the effect of AC noise in DC measurement
CMRR (Common Mode Rejection
Ratio)
Ratio)
U1211A and U1212A have CMRR specifi cations of >60 dB at DC to 60 Hz in the
ACV function; and > 80 dB at DC, 50 Hz and 60 Hz in the DCV function.
ACV function; and > 80 dB at DC, 50 Hz and 60 Hz in the DCV function.
U1213A has a CMRR specifi cations of >60 dB at DC to 60 Hz in the ACV function;
and > 120 dB at DC, 50 Hz and 60 Hz in the DCV function.
and > 120 dB at DC, 50 Hz and 60 Hz in the DCV function.
Operating temperature
-10 °C to 50 °C, 0 - 80 % R.H.
Storage temperature
-20 °C to 60 °C, 0 - 80 % R.H.
Relative Humidity (R.H.)
Maximum 80 % R.H. for temperature up to 31 °C decreasing linearly to 50 % R.H. at
50 °C
50 °C
Temperature coeffi cient
0.1 × (specifi ed accuracy) / °C (from 0 °C to 18 °C or 28 °C to 50 °C)
Safety compliance
EN/IEC 61010-1:2001, ANSI/UL 61010-1:2004, and CAN/CSA-C22.2 No.61010-1-04
Measurement category
CAT III 1000 V/ CAT IV 600 V
EMC compliance
Certifi ed to IEC61326-1:2005/ EN61326-1:2006
CISPR 11:2003/ EN 55011:2007 Group 1 class A
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS CISPR11:2004
CISPR 11:2003/ EN 55011:2007 Group 1 class A
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS CISPR11:2004