Gw Instek LCR-819 Digital-Multimeter, DMM, LCR-819 Ficha De Dados

Códigos do produto
LCR-819
Página de 2
E16
E15
Made to Measure.    
Good Will Instrument Co., Ltd.
FEATURES
LCR-821 (12Hz~200kHz)
12Hz~200kHz (LCR-821)
12Hz~100kHz (LCR-819/829)
12Hz~10kHz (LCR-817/827)
100Hz~2kHz (LCR-816/826)
* Test Frequency: 
* 0.05~0.1% Measurement Accuracy
* 100 Sets Memory for Save/Recall of 
Settings
* R/Q, C/D, C/R, L/Q Test Modes for all Models;
   Z/    , L/R for LCR-821 Only
* Absolute Value, Value, and % Measurement 
   Display
* 240 x 128 dot Matrix LCD Display
 Condition and Test Result
Displays
Simultaneously
* Interface : 
RS-232C (LCR-821/819/817/816)
                     Handler (LCR-829/827/826)
SPECIFICATIONS
TEST FREQUENCY
BASIC ACCURACY
TEST SPEED
TEST SIGNAL LEVELS
DC BIAS
DISPLAY RANGE
TEST MODE
EQUIVALENT CIRCUIT
MEMORY
AVERAGE
TEST SPEED MODE
DISPLAY MODE
DISPLAY
INTERFACE
POWER SOURCE
DIMENSIONS & WEIGHT
0.05% for basic accuracy for LCR-821/819/817
12Hz ~ 200kHz (504 steps) for LCR-821
5mV ~ 1.275Vrms ( 5mV/step ) for LCR-821/819/829/817/827 
0.1V ~ 1.275Vrms ( 5mV/step )for LCR-816/826 
R/Q , C/D, C/R, L/Q
Z/   , L/R for LCR-821 only
Parallel or s
 selectable
eries
100 memory blocks 
total
1 to 255 times
SLOW, MEDIUM and FAST
Value,      ,      %
240x128 dot matrix C.C.F.L back light LCD
Standard Interface : RS-232C for LCR-821
2V
0 ~ 35V  for LCR-821; 0 ~ 30V for LCR-819/829/817/827/816/826
Internal
External
AC 100V ~ 240V ,  47 ~ 63/400Hz
322 (W) x 149 (H)  x 433 (D)mm, Approx. 5.5kg
Resistance
Capacitance
Inductance
Quality Factor
Dissipation Factor
Impedance
Phase Angle ( Degree )
Line Voltage Range
0 .00001    ~  99999k
0.00001pF ~ 99999   F 
0.00001mH ~ 99999H 
0.0001 ~ 9999 
0.0001 ~ 9999 
0.00001     ~ 99999k for LCR-821
-180.00  ~ 180.00   for LCR-821
R
C
L
Q
D
Z
HIGH PRECISION LCR METER
LCR-817/827 (12Hz~10kHz)
LCR-819/829 (12Hz~100kHz)
0.1% for basic accuracy for LCR-829/827/826/816
68ms for LCR-821/819/817/816, 34ms for LCR-829/827/826
12Hz ~ 100kHz(503 steps) for LCR-819/829
12Hz ~ 10kHz(489 steps) for LCR-817/827
100Hz ~2kHz (245 steps) for LCR-816/826
Standard Interface : Handler Interface for LCR-829/827/826 
Optional : RS-232C Interface for LCR-819/817/816
 
(Including LCR-Viewer Software)
 (factory installed)
LCR-816/826(100Hz~2kHz)
12Hz~200kHz
(504 steps)
12Hz~100kHz
(503 steps)
240 x 128 dot matrix CCFL back light LCD
100 memory blocks totally
0.05%
2V
0 ~35V
Std.
Std.
Std.
Std.
Opt.
Opt.
Opt.
2V
0 ~30V
2V
0 ~30V
2V
0 ~30V
R/Q, C/D, C/R
L/Q, Z/   , L/R
R/Q, C/D, C/R,L/Q
R/Q, C/D, C/R,L/Q
R/Q, C/D, C/R,L/Q
0.05%
0.1%
0.05%
0.1%
0.1%
12Hz~10kHz
(489 steps)
100Hz~2kHz
(245 steps)
Test Frequency
Display
Memory
Basic Accuracy
Test Mode
DC BIAS
Interface
Internal
External
RS-232
Handler
MODEL
LCR-821
LCR-819
LCR-829
LCR-817
LCR-827
LCR-816
LCR-826
LCR-800 SERIES SELECTION GUIDE
Handler
B
A
S
IC
  T
 &
 M
 I
N
S
T
R
U
M
E
N
T
S
B
A
S
IC
  T
 &
 M
 I
N
S
T
R
U
M
E
N
T
S
LCR-821
 LCR-821 Rear Panel
 LCR-829 Rear Panel
 LCR-819 Rear Panel
LCR-05
LCR-06A
Patent:185538
Description: 
Test fixture for measurement 
of both axial and vertical 
lead components
Frequency: DC to 1MHz 
Max. Voltage: +/- 35V
Description: 
Kelvin clip test leads.
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
LCR-07
LCR-08  
Patent:188540
Description: 
Test leads for conventional 
component measurement. 
It is especially useful for high 
impedance measurement. 
(With alligator clips) 
Two-wire measurement; 
apply to low C or high R.
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
Description: 
SMD / clip tweezers
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
LCR-09
Patent:186171
Description: 
SMD / chip test fixture
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
LCR-13
Patent:186171
Description: 
SMD / chip test fixture
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
Size range from 0603 to 1812
Size range from 0201 to 0805
The LCR-800 Series are high-end digital LCR meters for component/material measurements, applicable 
to various R&D activities and assembly lines. The large 240 x 128 dot matrix LCD display provides 
ampleroom for two measurement items and setup parameters allowing you to grasp measurement 
results quickly. All test modes are able to measure supplementary factors such as, R/Q, C/D, C/R, and 
L/Q. The LCR-821 also contains precise resistance measurements as a combination of absolute value 
and phase angle. 100 sets of measurement setup memory allow sharing a single unit among multiple 
testing conditions or sites. For a better viewing experience with a standard PC monitor, proprietary 
Windows based software is accessible via the RS-232C terminal. The handler interface is also a 
standard feature for LCR-826/827/829.
ACCESSORIES :
User manual x 1, Power cord x1, LCR-06A x 1
LCR-821 200kHz High Precision LCR Meter with RS-232 Interface
LCR-05     Test Fixture for Axial & Radial Leaded Components 
Opt.01     RS-232C Interface ( Factory Installed ) 
LCR-06A   Kelvin Clip Test Lead
LCR-07      Test Fixture, Two-Wire with Alligator Clips
LCR-08      Test Fixture(Tweezers) for SMD/Chip Components
LCR-09      Test Fixture for SMD/Chip Components
LCR-13      Test Fixture for SMD/Chip Components
GRA-402   
 
Rack Adapter Panel, Rack Mounting (19", 4U)
GTL-232    RS232C Cable, 9-pin Female to 9-pin, null Modem for Computer
LCR-819
LCR-829
LCR-817
LCR-827
100kHz High Precision LCR Meter
100kHz High Precision LCR Meter with Handler Interface
10kHz High Precision LCR Meter 
10kHz High Precision LCR Meter with Handler Interface 
LCR-816 2kHz High Precision LCR Meter
LCR-826 2kHz High Precision LCR Meter with Handler Interface
Instrument Cart 
GTC-002
Instrument Cart 
GTC-001
ORDERING  INFORMATION
OPTION
OPTIONAL  ACCESSORIES
FREE DOWNLOAD
PC Software
LCR-Viewer
(**)
(*):Basic  accuracy  varies  with  the  speed,  frequency,  AC  signal  level  and  impedance  of  the  DUT.
(*)
(**):Display  range  refers  to  the  range  of  measurement  values  that  can  be  displayed  on  the  screen. 
     
Please  see  the  LCR-800  user  manual  for  the  effective  measurement  ranges.