Keithley 2002 Digital-Multimeter, DMM, 2002 Ficha De Dados
Códigos do produto
2002
D
IGI
TA
L M
U
LT
IM
E
TE
R
S &
S
Y
S
TEMS
A Greater Measure of Confidence
www.keithley.com
1.888.KEITHLEY
(U.S. only)
2001
2002
7½-Digit High Performance Multimeter
8½-Digit High Performance Multimeter
sErVICEs aVaIlablE
2000-SCAN-3Y-EW 1-year factory warranty extended to 3 years
from date of shipment
2001/MEM1-3Y-EW 1-year factory warranty extended to 3 years
from date of shipment
2001/MEM2-3Y-EW 1-year factory warranty extended to 3 years
from date of shipment
2001-SCAN-3Y-EW 1-year factory warranty extended to 3 years
from date of shipment
2001-TCSCAN-3Y-EW 1-year factory warranty extended to 3 years
from date of shipment
2001-3Y-EW
1-year factory warranty extended to 3 years
from date of shipment
from date of shipment
2002/MEM1-3Y-EW 1-year factory warranty extended to 3 years
from date of shipment
2002/MEM2-3Y-EW 1-year factory warranty extended to 3 years
from date of shipment
2002-3Y-EW
1-year factory warranty extended to 3 years
from date of shipment
from date of shipment
C/2000-3Y-ISO
3 (ISO-17025 accredited) calibrations within
3 years of purchase for Model 2000-SCAN*
3 years of purchase for Model 2000-SCAN*
C/2001-3Y-ISO
3 (ISO-17025 accredited) calibrations
within 3 years of purchase for Models 2001,
2001/MEM1, 2001/MEM2, 2001-SCAN,
2001-TCSCAN*
within 3 years of purchase for Models 2001,
2001/MEM1, 2001/MEM2, 2001-SCAN,
2001-TCSCAN*
C/2002-3Y-ISO
3 (ISO-17025 accredited) calibrations
within 3 years of purchase for Models 2002,
2002/MEM1, 2002/MEM2*
within 3 years of purchase for Models 2002,
2002/MEM1, 2002/MEM2*
*Not available in all countries
The built-in AC crest factor measurement helps
ensure the accuracy of AC measurements . Other
DMMs typically perform AC measurements for
signals without excessive crest factor—the ratio
of peak value to rms values . However, when
crest factor rises, measurements may not meet
specs . With a 2001 or 2002, there is no need for
an oscilloscope to determine if the crest factor is
acceptable—the DMM measures it directly .
While some DMMs calculate average AC from the
While some DMMs calculate average AC from the
rms value, these calculations apply only to sine
wave inputs . The 2001 and 2002 measure peak
value, average and true rms directly to obtain
a complete characterization of the signal . This
capability makes these DMMs ideal for AC circuit
design or test applications and for verifying test
voltages specified only in averages .
When measuring AC or digital signals, frequency
When measuring AC or digital signals, frequency
is critical . The 2001 and 2002 accurately meas-
ure frequency up to 15MHz . Accurate triggering
on the signal is critical to measure frequency
reliably . The frequency counters in the 2001
and 2002 have a fully adjustable trigger level for
good measurements of noisy signals .
Multiple Measurement Display
The 2001 and 2002 can display DC and AC volts
The 2001 and 2002 can display DC and AC volts
and the AC frequency from a single measure-
ment connection simultaneously . Several other
multiple-measurement displays are available,
including crest factor and bar graph . By meas-
uring sequentially and displaying simultaneously,
the 2001/2002 operates as if three different
meters are working together .
option slot Extends
DMM Performance
An option slot in the back of the 2001 and 2002
An option slot in the back of the 2001 and 2002
opens the door to a wide range of measurement
capabilities . Choose a 10-channel general-pur-
pose scanner card or a 9-channel thermocouple
scanner card to make measurements on multiple
test points or devices . This can eliminate the
need for a separate scanner and significantly
reduce programming and setup time .
aCCEssorIEs aVaIlablE
TEsT lEaDs aND ProbEs
5805
5805
Kelvin Probes, 0 .9m (3ft)
5805-12
Kelvin Probes, 3 .6m (12ft)
5808
Low Cost, Single Pin, Kelvin Probes
5809
Low Cost, Kelvin Clip Lead Set
8502
Micro-DIN to 6 BNCs Adapter Box with 8501-1 Cable
8530
Centronics Adapter
8605
High Performance 2-Wire Modular Test Leads
8606
High Performance Modular Probe Kit
8610
Low Thermal Shorting Plug
8680
RTD Probe Adapter
8681
Low Cost RTD
CablEs/aDaPTErs
7007-1
7007-1
Shielded GPIB Cable, 1m (3 .3 ft)
7007-2
Shielded GPIB Cable, 2m (6 .6 ft)
8501-1
Trigger-Link Cable, 1m (3 .3 ft)
8501-2
Trigger Link Cable, 2m (6 .6 ft)
8502
Trigger Link Adapter Box
8610
Low Thermal Shorting Plug
8620
4-Wire DMM Shorting Plug
raCK MouNT KITs
4288-1
4288-1
Single Fixed Rack Mount Kit
4288-4
Side-by-Side Rack Mount Kit
GPIb INTErfaCEs
KPCI-488LPA IEEE-488 Interface Controller for the PCI Bus
KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter
KPCI-488LPA IEEE-488 Interface Controller for the PCI Bus
KUSB-488B IEEE-488 USB-to-GPIB Interface Adapter
H
ig
h r
es
ol
ut
io
n,
h
ig
h ac
cu
rac
y D
M
M
s
H
ig
h r
es
ol
ut
io
n,
h
ig
h ac
cu
rac
y D
M
M
s