Keithley 2002 Digital-Multimeter, DMM, 2002 Ficha De Dados

Códigos do produto
2002
Página de 6
D
IGI
TA
L M
U
LT
IM
E
TE
R
S &
 S
Y
S
TEMS
A Greater Measure of Confidence
www.keithley.com
1.888.KEITHLEY 
(U.S. only)
2001
2002
7½-Digit High Performance Multimeter 
8½-Digit High Performance Multimeter
sErVICEs aVaIlablE
2000-SCAN-3Y-EW  1-year factory warranty extended to 3 years 
from date of shipment
2001/MEM1-3Y-EW  1-year factory warranty extended to 3 years 
from date of shipment
2001/MEM2-3Y-EW  1-year factory warranty extended to 3 years 
from date of shipment
2001-SCAN-3Y-EW  1-year factory warranty extended to 3 years 
from date of shipment
2001-TCSCAN-3Y-EW 1-year factory warranty extended to 3 years 
from date of shipment
2001-3Y-EW 
1-year factory warranty extended to 3 years 
from date of shipment
2002/MEM1-3Y-EW  1-year factory warranty extended to 3 years 
from date of shipment
2002/MEM2-3Y-EW  1-year factory warranty extended to 3 years 
from date of shipment
2002-3Y-EW 
1-year factory warranty extended to 3 years 
from date of shipment
C/2000-3Y-ISO 
3 (ISO-17025 accredited) calibrations within 
3 years of purchase for Model 2000-SCAN*
C/2001-3Y-ISO 
3 (ISO-17025 accredited) calibrations 
within 3 years of purchase for Models 2001, 
2001/MEM1, 2001/MEM2, 2001-SCAN, 
2001-TCSCAN*
C/2002-3Y-ISO 
3 (ISO-17025 accredited) calibrations 
within 3 years of purchase for Models 2002, 
2002/MEM1, 2002/MEM2*
*Not available in all countries
The built-in AC crest factor measurement helps 
ensure the accuracy of AC measurements . Other 
DMMs typically perform AC measurements for 
signals without excessive crest factor—the ratio 
of peak value to rms values . However, when 
crest factor rises, measurements may not meet 
specs . With a 2001 or 2002, there is no need for 
an oscilloscope to determine if the crest factor is 
acceptable—the DMM measures it directly .
While some DMMs calculate average AC from the 
rms value, these calculations apply only to sine 
wave inputs . The 2001 and 2002 measure peak 
value, average and true rms directly to obtain 
a complete characterization of the signal . This 
capability makes these DMMs ideal for AC circuit 
design or test applications and for verifying test 
voltages specified only in averages .
When measuring AC or digital signals, frequency 
is critical . The 2001 and 2002 accurately meas-
ure frequency up to 15MHz . Accurate triggering 
on the signal is critical to measure frequency 
reliably . The frequency counters in the 2001 
and 2002 have a fully adjustable trigger level for 
good measurements of noisy signals .
Multiple Measurement Display
The 2001 and 2002 can display DC and AC volts 
and the AC frequency from a single measure-
ment connection simultaneously . Several other 
multiple-measurement displays are available, 
including crest factor and bar graph . By meas-
uring sequentially and displaying simultaneously, 
the 2001/2002 operates as if three different 
meters are working together .
option slot Extends 
DMM Performance
An option slot in the back of the 2001 and 2002 
opens the door to a wide range of measurement 
capabilities . Choose a 10-channel general-pur-
pose scanner card or a 9-channel thermocouple 
scanner card to make measurements on multiple 
test points or devices . This can eliminate the 
need for a separate scanner and significantly 
reduce programming and setup time . 
aCCEssorIEs aVaIlablE
TEsT lEaDs aND ProbEs 
5805 
Kelvin Probes, 0 .9m (3ft)
5805-12 
Kelvin Probes, 3 .6m (12ft)
5808 
Low Cost, Single Pin, Kelvin Probes
5809 
Low Cost, Kelvin Clip Lead Set
8502 
Micro-DIN to 6 BNCs Adapter Box with 8501-1 Cable
8530 
Centronics Adapter
8605 
High Performance 2-Wire Modular Test Leads
8606 
High Performance Modular Probe Kit
8610 
Low Thermal Shorting Plug
8680 
RTD Probe Adapter
8681 
Low Cost RTD
CablEs/aDaPTErs 
7007-1 
Shielded GPIB Cable, 1m (3 .3 ft)
7007-2 
Shielded GPIB Cable, 2m (6 .6 ft)
8501-1 
Trigger-Link Cable, 1m (3 .3 ft)
8501-2  
Trigger Link Cable, 2m (6 .6 ft)
8502 
Trigger Link Adapter Box
8610 
Low Thermal Shorting Plug
8620 
4-Wire DMM Shorting Plug
raCK MouNT KITs
4288-1 
Single Fixed Rack Mount Kit
4288-4 
Side-by-Side Rack Mount Kit
GPIb INTErfaCEs
KPCI-488LPA IEEE-488 Interface Controller for the PCI Bus
KUSB-488B  IEEE-488 USB-to-GPIB Interface Adapter
H
ig
h r
es
ol
ut
io
n,
 h
ig
h ac
cu
rac
y D
M
M
s
H
ig
h r
es
ol
ut
io
n,
 h
ig
h ac
cu
rac
y D
M
M
s