Freescale Semiconductor FRDM-FXS-MULTI-B Ficha De Dados

Página de 42
MPL3115A2
Sensors
Freescale Semiconductor, Inc.
5
2
Mechanical and Electrical Specifications
2.1
Mechanical Characteristics
Table 2. Mechanical Characteristics @ V
DD
 = 2.5 V, T = 25 °C unless otherwise noted
(1)
1. Measured at 25 °C, over 50 kPa to 110 kPa.
Ref
Symbol
Parameter
Test Conditions
Min
Typ
Max
Unit
Pressure Sensor
1
P
FS
Measurement Range
Calibrated Range
50
110
kPa
Operational Range
20
110
kPa
2
Pressure Reading Noise
1x Oversample
(2)
2. Oversample (OSR) modes internally combine and average samples to reduce noise.
19
Pa RMS
128x Oversample
(2)
1.5
Pa RMS
3
Pressure Absolute Accuracy 
50 to 110 kPa
 over 0 °C to 50 °C
-0.4
0.4
kPa
50 to 110 kPa
over -10 °C to 70 °C
±0.4
4
Pressure Relative Accuracy
Relative accuracy during 
pressure change between
70 to 110 kPa at any constant 
temperature between
-10 °C to 50 °C
±0.05
kPa
Relative accuracy during 
changing temperature between 
-10 °C to 50 °C at any constant 
pressure between 50 kPa to 
110 kPa
±0.1
5
Pressure/Altitude Resolution
(3)(4)(5)
3. Smallest bit change in register represents minimum value change in Pascals or meters. Typical resolution to signify change in altitude is 0.3  m.
4. At 128x Oversample Ratio.
5. Reference pressure = 101.325 kPa (Sea Level).
Barometer Mode
0.25 
1.5
Pa
Altimeter Mode
0.0625
0.3
m
6
Output Data Rate
OST
(6)
 Mode
6.  OST = One Shot Mode.
100
Hz
FIFO Mode
1
Hz
Temperature Sensor
7
T
FS
Measurement Range
-40
+85
°C
8
Temperature Accuracy
@ 25 °C
±1
°C
Over Temperature Range
±3
9
T
OP
Operating Temperature Range
-40
+85
°C
10
Board Mount Drift
After solder reflow
±0.15
kPa
11
Long Term Drift 
After a period of 1 year
±0.1
kPa