Note: 
Phase sequence tests can be carried out even with 
the batteries being removed or exhausted.
5. LED torch
Warning!
Potentially dangerous optical radiation!
Do not look directly or indirectly via 
reflecting surfaces into the LED beam! 
Danger to your retina!
-  The device is provided with a high-power LED 
torch 6 with can be switched on and off by press-
ing the push-button 7.
6.  Battery replacement
-   Do not apply voltage to the device when the bat-
tery compartment is open! 
-  The battery compartment is located on the back of 
the device.
-  Slightly press down the catch  by means of a 
screwdriver and push off the battery compartment 
cover  in downward direction at the same time. 
-  Replace the exhausted batteries by three new 
ones of type AA (LR06). Make sure that the new 
batteries are inserted with correct polarity!
-  Push the battery compartment cover  back onto 
the housing until the catch  locks into place with 
an audible click.
Note:
The battery compartment cover  is provided with an 
integrated magnet and a belt clip for attachment of the 
device.
7.  Technical data
-  Regulations: DIN EN 61010-1 and -031, IEC 
61010-1 and -31, DIN EN 61557-1 and -7, IEC 
61557-1 and -7, DIN EN 62471
-  Nominal voltage range: 400 V to 500 V
-  Measuring category: CAT III 300 V to earth
-  Nominal frequency range f: 50 Hz / 60 Hz 
-  Current consumption: I
s
 < 3.5 mA (500 V)
-  Contamination level: 2
-  Protection category: IP 40 (DIN VDE 0470-1 IEC / 
EN 60529)
4 - first index: protection against access to dan-
gerous parts and protection against solid impuri-
ties of a diameter > 1.0 mm
0 - second index: no protection against water
-  Battery: 3 x 1.5 V batteries of type AA (LR06) 
-  Weight: approx. 250 g
-  Measuring line with test handles: length of approx. 
1,000 mm
-  Operating temperature range: - 15 °C to + 55 °C
-  Storage temperature range: - 15 °C to + 55 °C 
-  Relative air humidity: 20 % to 80 %
8.  General maintenance
Clean the exterior of the device with a clean dry cloth. 
If there is contamination or deposits in the area of the 
battery or the battery housing, clean these areas as 
well by means of a dry cloth.
If the device is stored for a longer period of time, 
remove the batteries from the device!
9.  Environmental protection 
At the end of product life, dispose of the 
unserviceable device as well as used batte-
ries via appropriate collecting facilities provi-
ded in your community.