Instruction manual      2050E 
®
UNITEST       MAGNO-VOLTfix
Instruction:
Symbols on the instrument and in the 
instruction manual:
the operating ranges as specified in the 
Display and Control Elements:
Testing of Sockets-  and lead 
Phase tester of sockets
Th e c on ta ct -f re e v ol ta ge  te st er  
technical 
data 
section.
1) 
Test 
probe
connection wiring:
Conventional 1.5 V batteries IEC LR03
Voltmagfinger has been developed for 
2) LED for voltage indication
Safety measures
voltage testing  on insulated  cables and 
3) Battery case cover and location for 
#
 Warning !
+
Danger! 
The instrument has left our factory in a 
conductors.  For  testing,  no  electrical 
    magnetic field indication
The test instrument may only be used in 
In order to avoid the danger of electrical 
safe and perfect condition. To maintain 
connection to UUT is required. A second 
p r o p e r l y   g r o u n d e d   e l e c t r i c a l  
shock, it is important that proper safety 
this condition, the user must pay 
connection, e.g. to neutral or ground is 
installations.
measures are respected when working 
attention to the safety references 
Warning! Warns of potential 
#
not necessary.
with voltages exceeding 120V (60V) DC 
contained in this instruction manual. 
danger, comply with the Instruction 
The second instrument function is the 
or 50V (25V) r.m.s. AC. These voltages 
#
 Warning !
manual.
recognition of a magnetic field, e.g. of 
represent internationally the limits of 
#
Warning!
The opening of the instrument for fuse 
relays, contactors, and magnetic valves. 
max. contact voltage.
This instruction manual contains both 
replacement, for example, may only be 
The Voltmagfinger does not require 
Caution! Dan ger ous  vol tag e. 
information and warnings that are 
+
carried out by professionals. Prior to 
maintenance. It is equipped with 
Danger of electrical shock.
necessary for the safe operation and 
Warning! 
#
opening, the instrument has to be 
protective insulation. Power is supplied 
maintenance of the instrument. It is 
The voltage tester is appropriate for AC 
switched off and disconnected from any 
by means of two conventional micro 
recommended that you read the manual 
voltages between 50V and 600 V AC. A 
current circuit.
batteries 1.5 V IEC LR03. 
Continuous double or reinforced 
-
carefully and ensure that its contents are 
perfect instrument function is only 
insulation complies to IEC 536, Class II
Warning! 
fully understood. Failure to understand 
#
ensured within a temperature range of 0 
Features:
The instrument must only be used under 
these instructions and to comply with 
... 40°C, >80 % humidity.
Contact-free voltage test 50 V...600 V AC
the conditions and for the purposes for 
the warnings and instructions contained 
Symbol of conformity, confirms 
,
Display via LED (blinking) Acoustic 
which it has been constructed. particular 
herein can result in serious injury or 
conformity with relevant EU directives. 
Warning! 
#
sound signal (pulsating)
attention should be paid to the safety 
damage. 
The instrument complies with the EMC 
The signal during the voltage test does 
instructions, the technical speci-
Contact-free testing of AC voltages on 
Directive (89/336/EEC) specifically  
not provide any indication of the type and 
#
Warning!
fications relating to environmental 
standards EN 50081-1:1992 and EN 
insulated cables and conductors
level of voltage present.  In case of 
Only touch the instrument handle for any 
conditions and the use of the instrument 
50082-1:1997, as well as  the Low 
Locating line interruptions in insulated 
doubt, measure the voltage by using a  
voltage test.
in dry surroundings.
Voltage Directive (73/23/EEC) described 
cables and conductors
test instrument with display indication.
in  the   standard EN 61010-1:1995.
Recognition of the magnetic field of 
After inserting the batteries, the 
#
Warning!
relays, contactors, and magnetic  valves
Voltmagfinger is ready for operation.
The instrument may only be used within 
The blinking LED and the pulsating 
Maintenance
! Remove discharged battery and 
recycling and disposal of used batteries 
tampered with, and is returned to us 
signal sound indicate that a voltage 
As long as the instructions in the 
insert new ones by respecting correct 
and 
accumulators.
unopened. Damage due to dropping, 
presence of a value between 50V and 
operating manual  are adhered  to, no 
polarity. For battery type, please refer 
abuse or misuse is not covered by the 
600 V AC has been recognised, at a 
special maintenance is required.
to the technical data section.
Technical Data
guarantee.
frequency of 50 to 500 Hz. 
! Carefully press battery case cover 
Voltage range: 
50...600V AC
Our Service Department will promptly 
Cleaning:
until latching.
Frequency range:
50Hz...500Hz
repair any faults that occur outside 
Disconnect  the  instrument  from  all 
Display: 
        Clear, omnidirectional 
the guarantee period.
When testing mains connecting cables 
circuits. Humidify the cloth slightly with 
        flashing beacon
for interruptions the user must ensure 
household  cleaner    and  wipe  the 
IP-Protection: 
IP40
Please contact:
that both lines are connected once to 
Recognition of a Magnetic Field
instrument surface by applying light 
Overvoltage category:  CAT III, 600V
phase (L).  (Turn shockproof plugs  by 
To enable recognition of a magnetic field, 
pressure.  Allow  a  recovery  time  of  6 
Pollution degree: 
2
180°).
the instrument has to be reversed
hours after cleaning before operating the 
Altitude:
up to  2000m
Ch.Beha GmbH
#
Warning !
instrument.
Temperature range:
0°C up to 40°C
In den Engematten 14
Application example
Humidity:
<80%
D-79286 Glottertal
Battery Replacement
Power supply:    2x 1,5V batt. IEC LR03
1)Open battery case cover (3) by using 
Dimensions:
140x25x21mm
Applikation examples:
a screwdriver or similar.
Weight:
Approx.50g
This Instruction Manual has been 
prepared with great care. No liability 
is accepted for the correctness and 
12 months' guarantee
completeness of the data, 
The instruments are subject to 
illustrations, and drawings it 
stringent quality controls. If, in the 
contains.
course of normal daily use, a fault 
 
should occur, we provide 12 months' 
We reserve the right to make  
guarantee (only valid with invoice). 
#
Warning !
technical alterations.
Faults in manufacture and materials 
Please, comply with the appropriate 
will be rectified by us free of charge, 
regulations concerning the return, 
provided the instrument has not been 
220999ma - 7108-UT2050DD21-UK
If the instrument is likely to remain 
:
unused for a long period of time the 
batteries must be removed. If a battery 
should leak inside the housing, return 
the instrument to our service 
department  for cleaning and checking.
Please think of our environment when 
getting rid of used batteries. They should 
be disposed of in a place suitable for 
hazardous waste.
Close battery cover
3
1
2
Locating line interruptions
i.e. cable drums, etc.
Voltage test at insulated 
conductors
Phase finding on socket outlets
Open
battery cover
Signal
No signal
Magnetic field recognition e.g. relays, contactors 
and magnetic valve etc.
This point is marking the
location of max. sensitivity
for magnetic sensor.