Beha Amprobe UNITEST MAGNO-VOLTFIX Multi-Tester CAT III 600 V 2146291 Ficha De Dados
Códigos do produto
2146291
Instruction manual 2050E
®
UNITEST MAGNO-VOLTfix
Instruction:
Symbols on the instrument and in the
instruction manual:
instruction manual:
the operating ranges as specified in the
Display and Control Elements:
Testing of Sockets- and lead
•
Phase tester of sockets
Th e c on ta ct -f re e v ol ta ge te st er
technical
data
section.
1)
Test
probe
connection wiring:
•
Conventional 1.5 V batteries IEC LR03
Voltmagfinger has been developed for
2) LED for voltage indication
Safety measures
voltage testing on insulated cables and
3) Battery case cover and location for
#
Warning !
+
Danger!
The instrument has left our factory in a
conductors. For testing, no electrical
magnetic field indication
The test instrument may only be used in
In order to avoid the danger of electrical
safe and perfect condition. To maintain
connection to UUT is required. A second
p r o p e r l y g r o u n d e d e l e c t r i c a l
shock, it is important that proper safety
this condition, the user must pay
connection, e.g. to neutral or ground is
installations.
measures are respected when working
attention to the safety references
Warning! Warns of potential
#
not necessary.
with voltages exceeding 120V (60V) DC
contained in this instruction manual.
danger, comply with the Instruction
The second instrument function is the
or 50V (25V) r.m.s. AC. These voltages
#
Warning !
manual.
recognition of a magnetic field, e.g. of
represent internationally the limits of
#
Warning!
The opening of the instrument for fuse
relays, contactors, and magnetic valves.
max. contact voltage.
This instruction manual contains both
replacement, for example, may only be
The Voltmagfinger does not require
Caution! Dan ger ous vol tag e.
information and warnings that are
+
carried out by professionals. Prior to
maintenance. It is equipped with
Danger of electrical shock.
necessary for the safe operation and
Warning!
#
opening, the instrument has to be
protective insulation. Power is supplied
maintenance of the instrument. It is
The voltage tester is appropriate for AC
switched off and disconnected from any
by means of two conventional micro
recommended that you read the manual
voltages between 50V and 600 V AC. A
current circuit.
batteries 1.5 V IEC LR03.
Continuous double or reinforced
-
carefully and ensure that its contents are
perfect instrument function is only
insulation complies to IEC 536, Class II
Warning!
fully understood. Failure to understand
#
ensured within a temperature range of 0
Features:
The instrument must only be used under
these instructions and to comply with
... 40°C, >80 % humidity.
•
Contact-free voltage test 50 V...600 V AC
the conditions and for the purposes for
the warnings and instructions contained
Symbol of conformity, confirms
,
•
Display via LED (blinking) Acoustic
which it has been constructed. particular
herein can result in serious injury or
conformity with relevant EU directives.
Warning!
#
sound signal (pulsating)
attention should be paid to the safety
damage.
The instrument complies with the EMC
The signal during the voltage test does
instructions, the technical speci-
•
Contact-free testing of AC voltages on
Directive (89/336/EEC) specifically
not provide any indication of the type and
#
Warning!
fications relating to environmental
standards EN 50081-1:1992 and EN
insulated cables and conductors
level of voltage present. In case of
Only touch the instrument handle for any
conditions and the use of the instrument
50082-1:1997, as well as the Low
•
Locating line interruptions in insulated
doubt, measure the voltage by using a
voltage test.
in dry surroundings.
Voltage Directive (73/23/EEC) described
cables and conductors
test instrument with display indication.
in the standard EN 61010-1:1995.
•
Recognition of the magnetic field of
After inserting the batteries, the
#
Warning!
relays, contactors, and magnetic valves
Voltmagfinger is ready for operation.
The instrument may only be used within
The blinking LED and the pulsating
Maintenance
! Remove discharged battery and
recycling and disposal of used batteries
tampered with, and is returned to us
signal sound indicate that a voltage
As long as the instructions in the
insert new ones by respecting correct
and
accumulators.
unopened. Damage due to dropping,
presence of a value between 50V and
operating manual are adhered to, no
polarity. For battery type, please refer
abuse or misuse is not covered by the
600 V AC has been recognised, at a
special maintenance is required.
to the technical data section.
Technical Data
guarantee.
frequency of 50 to 500 Hz.
! Carefully press battery case cover
Voltage range:
50...600V AC
Our Service Department will promptly
Cleaning:
until latching.
Frequency range:
50Hz...500Hz
repair any faults that occur outside
Disconnect the instrument from all
Display:
Clear, omnidirectional
the guarantee period.
When testing mains connecting cables
circuits. Humidify the cloth slightly with
flashing beacon
for interruptions the user must ensure
household cleaner and wipe the
IP-Protection:
IP40
Please contact:
that both lines are connected once to
Recognition of a Magnetic Field
instrument surface by applying light
Overvoltage category: CAT III, 600V
phase (L). (Turn shockproof plugs by
To enable recognition of a magnetic field,
pressure. Allow a recovery time of 6
Pollution degree:
2
180°).
the instrument has to be reversed
hours after cleaning before operating the
Altitude:
up to 2000m
Ch.Beha GmbH
#
Warning !
instrument.
Temperature range:
0°C up to 40°C
In den Engematten 14
Application example
Humidity:
<80%
D-79286 Glottertal
Battery Replacement
Power supply: 2x 1,5V batt. IEC LR03
1)Open battery case cover (3) by using
Dimensions:
140x25x21mm
Applikation examples:
a screwdriver or similar.
Weight:
Approx.50g
This Instruction Manual has been
prepared with great care. No liability
is accepted for the correctness and
12 months' guarantee
completeness of the data,
The instruments are subject to
illustrations, and drawings it
stringent quality controls. If, in the
contains.
course of normal daily use, a fault
should occur, we provide 12 months'
We reserve the right to make
guarantee (only valid with invoice).
#
Warning !
technical alterations.
Faults in manufacture and materials
Please, comply with the appropriate
will be rectified by us free of charge,
regulations concerning the return,
provided the instrument has not been
220999ma - 7108-UT2050DD21-UK
If the instrument is likely to remain
:
unused for a long period of time the
batteries must be removed. If a battery
should leak inside the housing, return
the instrument to our service
department for cleaning and checking.
batteries must be removed. If a battery
should leak inside the housing, return
the instrument to our service
department for cleaning and checking.
Please think of our environment when
getting rid of used batteries. They should
be disposed of in a place suitable for
hazardous waste.
getting rid of used batteries. They should
be disposed of in a place suitable for
hazardous waste.
Close battery cover
3
1
2
Locating line interruptions
i.e. cable drums, etc.
Voltage test at insulated
conductors
Phase finding on socket outlets
Open
battery cover
Signal
No signal
Magnetic field recognition e.g. relays, contactors
and magnetic valve etc.
and magnetic valve etc.
This point is marking the
location of max. sensitivity
for magnetic sensor.
location of max. sensitivity
for magnetic sensor.