Ea Elektro Automatik EA Elektro-Automatik EA-EL 9160-300 HP Electronic Load 0 - 300 A 0 - 160 Vdc 0 - 7200 W 33200247 Ficha De Dados

Códigos do produto
33200247
Página de 52
29
Instruction Manual
EL 9000 HP Series
EN
Date: 10-31-2011
About the device
1.  Introduction
The electronic loads of the series EL 9000 HP are very 
efficient devices which offer a big variety of interesting 
features in a 19“ case of 9U. Besides the common func-
tionality of electronic loads you can test batteries, load 
voltage or current sources with a pulsed operation, where 
the pulse widths and the amplitude are adjustable. Or 
you can remotely control the device via an interface card 
and control and monitor nearly all its features from a PC.
The integration into existing systems is made easy by 
using    one  of  the  interface  cards,  the  configuration  is 
intuitive and is done at the device. The electronic loads 
can thus be operated in conjunction with a power supply 
or, with the additional analogue interface socket at the 
rear side, controlled and monitored by any other device 
with an analogue interface.
The device is microprocessor controlled. This results in 
an accurate and fast measurement and display of actual 
values, as well as an extended operability by many new 
features which wouldn‘t be realisable with standard ana-
logue technology.
The  modern  design  offers  highest  performance  and 
enables  space-saving  conceptioning  of  complex  and 
efficient  applications,  like  for  example  industrial  test 
equipment  with  variable  powers  for  different  demands 
or for demonstration and test purposes in the research 
and development area.
The  digital  control  and  the  retrofittable  interface  card 
strongly simplify the connection to professional, industrial 
bus systems like CAN. Nearly all possibilities of the single 
systems are used. With USB you can plug and use up to 
four (or more) devices to a standard PC without the need 
of additional hardware. At CAN you can implement the 
devices into existing CAN bus systems without the need 
to reconfigure the whole bus system. Address range and 
transmissions speed can be selected for the particular 
EL 9000 HP unit, so it fits best.
The main functions at a glance:
•  Set U, I, P and R, each 0...100%
•  Battery test with Ah and time count
•  Pluggable interface cards (CAN, USB, RS232, IEEE/
GPIB, Ethernet/LAN)
•  Analogue interface for external control
•  Pulsed operation between two set values with adjusta-
ble pulse widths and adjustable rise/fall time
•  Adjustable  duty  cycle  (as  time)  of  50µs...100s  and 
adjustable rise time of 30µs...200ms
•  Vector software compatible CAN system
2.  Technical specifications
2.1  Control panel
Type
Display:      
two line character display with    
            
80 characters
Operating elements:  2 rotary knobs, 2 rotary switches,
            
1 pushbutton
Display formats 
The nominal values determine the adjustable range.
Actual and set values are displayed all at once, as long 
as the currently active operation mode allows it.
 
Display of voltage values 
Resolution:    
3 or 4 digits 
Formats:      
0.00V…99.99V 
            
0.0V…999.9V 
Display of current values 
Resolution:    
4 digits 
Formats:      
0.09A…99.99A 
            
0.0A…999.9A 
Display of power values
Resolution:    
4 digits 
Formats:      
0W…9999W
Display of resistance values
Resolution:    
4 digits 
Formats:      
0.000Ω…9.999Ω 
            
0.00Ω...99.99Ω 
            
0.0Ω...999.9Ω
Display of time
The elapsed time (only battery test mode) is display in 
the format Hours:Minutes:Seconds (HH:MM:SS).
Resolution:    
1s 
Range:       
1s...99h:59m:59s (99:59:59)
This time stamp can be read out via one of the pluggable 
interface cards, together with the pulse widths and rise 
time of the dynamic Level A/B operation. The dynamic 
values can also be set remotely.
Detailed information about this can be found in the in-
struction manual of the interface cards.