Examples of digital out use
PicoScope
The following is a short example of how to activate an LED via a digital output on the
USB DrDAQ using the 
M ask and A larm functions of PicoScope. With USB DrDAQ
connected and PicoScope open:
Connect the LED to the 
G N D connection on the USB DrDAQ and digital connection 2
(refer to Connections).
    Note: Any digital connection can be used but we are using 
2 in this example).
Within PicoScope, activate the 
Tem p channel only (refer to displaying channels).
Under the 
Tools menu, choose M asks> A dd M asks.
Choose 
M ask of Tem p within the A vailable M asks area, or click G en erate if it doesn't
show in the Library list.
Click 
A pply and choose O K.
Right click the oscilloscope window and choose 
M asks> Edit M ask.
Within the mask dialogue, adjust the two low values to 28°C.
Right click the oscilloscope window and choose 
M asks> Exit M ask Edit.
Under 
Tools menu, choose A larm s.
Under 
Even t, choose M ask(s) Fail (ensure it is enabled).
Choose 
A dd.
Under 
A ction menu, choose D igital O u tpu t.
Set 
C h an n to D igital O u tpu t 2, and H igh.
Choose 
O K.
Click 
A pply and choose O K .
Start the trace and place the tip of a finger onto the 
Tem p sensor on the USB
DrDAQ. The trace should rise, and upon overlapping the mask, the LED connected
to digital connection 
2 should illuminate.
PicoLog
The following is a short example of how to activate an LED via a digital output on the
USB DrDAQ using the 
A larm function of PicoLog. With USB DrDAQ connected and
PicoLog open:
Connect the LED to the 
G N D connection on the USB DrDAQ and digital connection 2
(refer to Connections).
    Note: Any digital connection can be used but we are using 
2 in this example).
Choose 
File> N ew  settin gs.
Click
 O K .
Click
 O K .
Choose 
C on verter type: D rD A Q  (U S B ).
Click
 O K .
Click 
A dd.
Next to 
C h an n el, choose Tem peratu re.
Choose 
O ption s.
Choose 
A larm .
Select 
En able A larm .
Enter the 
U pper th resh old 28°C .
Select 
D igital O u tpu t 2.
Click the next four 
O K  buttons.
Place a finger tip on the 
Tem p sensor, an alarm will trigger once the temperature
goes above the upper threshold entered earlier, when this happens the LED will
illuminate, along with the red alarm icon in PicoLog. When you remove your finger,
the LED will extinguish (once the temperature drops back below the upper
threshold value).