Atmel Xplained Pro Evaluation Kit ATSAM4E-XPRO ATSAM4E-XPRO Ficha De Dados

Códigos do produto
ATSAM4E-XPRO
Página de 1506
SAM4E [DATASHEET]
Atmel-11157D-ATARM-SAM4E16-SAM4E8-Datasheet_12-Jun-14
616
CFDEV: Clock Failure Detector Event
0: No clock failure detection of the fast crystal oscillator clock has occurred since the last read of PMC_SR.
1: At least one clock failure detection of the fast crystal oscillator clock has occurred since the last read of PMC_SR.
CFDS: Clock Failure Detector Status
0: A clock failure of the fast crystal oscillator clock is not detected.
1: A clock failure of the fast crystal oscillator clock is detected.
FOS: Clock Failure Detector Fault Output Status
0: The fault output of the clock failure detector is inactive.
1: The fault output of the clock failure detector is active.