Atmel SAM4S-EK2 Atmel ATSAM4S-EK2 ATSAM4S-EK2 Ficha De Dados
![Atmel](https://files.manualsbrain.com/attachments/0369829915bda09f9c2e00fb805a7753579683b5/common/fit/150/50/8d2bf08978ec3e5bc63f4343ac5e91ce8d0e40045619fa520d910d64af8f/brand_logo.png)
Códigos do produto
ATSAM4S-EK2
903
SAM4S [DATASHEET]
11100E–ATARM–24-Jul-13
38.7.22 PWM Output Selection Clear Update Register
Name:
PWM_OSCUPD
Address:
0x40020058
Access:
Write-only
• OSCUPHx: Output Selection Clear for PWMH output of the channel x
0 = No effect.
1 = Dead-time generator output DTOHx selected as PWMH output of channel x at the beginning of the next channel x PWM
period.
period.
• OSCUPLx: Output Selection Clear for PWML output of the channel x
0 = No effect.
1 = Dead-time generator output DTOLx selected as PWML output of channel x at the beginning of the next channel x PWM
period.
period.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
OSCUPL3
OSCUPL2
OSCUPL1
OSCUPL0
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
–
–
–
–
OSCUPH3
OSCUPH2
OSCUPH1
OSCUPH0