Aurel 650200627 433MHz Radio Component 650200627 Ficha De Dados

Códigos do produto
650200627
Página de 3
                                                                 WIZ-SML-IA 
                                                                                                                                   Instruction Manual  
Technical features are subject to change without notice. AUR°EL S.p.A does not assume responsibilities for any damage caused by the device’s misuse. 
 
AUR°EL S.p.A.
 Via Foro dei Tigli, 4 - 47015 Modigliana [FC] – ITALY                                                                  Rev. A, 01-04-2002 
Tel.: +390546941124 – Fax: +390546941660                                                                                                                Pag  1 di 3 
http://www.aurel.it
  -  email: 
aurel@aurel.it
 
Data transmission by the WIZ-SML-IA module 
 
The WIZ-SML-IA modules are transceivers for point-to-point data transfer in half-duplex mode. They are the 
right solution for all those applications in which the so called “virtual cable” has to be implemented, i.e. the 
RF connection of two systems with RS232 output (for instance two PCs.) The  WIZ-SML-IA module is 
available in 12V and 5V version: in the first case the voltage is supplied by a connector with central positive 
Vcc, while in the 5V version the voltage is supplied through the input 10 of the data connector. Connected to 
the module can be used W232 ADAPTER connector which foresees inside an integrated circuit which shall 
care for the conversion of the electric signals from RS232 logic to TTL logic and vice versa. 
The module has very small dimensions (4 x 9 cm only) and in its card integrates a 100 kbps XTR transceiver, 
a microprocessor which administrates the RF syncronizing protocol and a tuned antenna realized on a 
printed circuit. Besides these components is fitted also a confirguration dip-switch with 6 positions and 2 
indication LED (supply and operation). 
The module is enclosed in a special case which complies with the  EN 61000-4-2 rule. 
 
 
 
 
Module’s 12 V supply  
 
By means of a connector with positive pole at central pin, 9V-15V DC voltage supply  
 
 
Module’s 5V supply 
 
Input no. 10 of the data connector (see below). 
 
Data connector 
 
 
1. TX Data (IN) 
2. XTR analogic output (OUT) 
3. GND 
4. GND 
5. RX Data (OUT) 
6. XTR Carrier Detect (OUT) 
7. CTS not in use (OUT) 
8. LED (OUT) 
9. RTS not in  use (IN) 
10. 5V DC (IN/OUT) 
 
 
Front view 
10