Secutech Radio modules ST002012 Ficha De Dados

Códigos do produto
ST002012
Página de 32
Page 14
 
Security & Electronic Technologies GmbH
 
 
 
Terminals: 
SECU-DATA 142xM/142xC (4-20mA) 
 
Terminal  Signal, function 
1  Plus-pole of power supply (
+11 V … +40 V), 
reverse polarity protection by two 2 diodes 
2  Ground line of power supply (0 V) 
3   Measuring signal 4-20 mA, positive pole,   
SECU-DATA 142xM: input, for connection of the 
probe 
SECU-DATA 142xC: output, for connection of 
the evaluation equipment 
4   Measuring signal 4-20 mA, negative pole,  
SECU-DATA 142xM: input, for connection of the 
probe  
SECU-DATA 142xC: output, for connection of 
the evaluation equipment 
5  Not connected 
6, 7, 8   Relay contacts, passive, for monitoring the sta-
tus of the RF-connection 
7 is the root, for active RF-connection terminals 
6-7 are interconnected, during RF-interruptions 
terminals 7-8 are interconnected. 
Rated switching capacity: 30 V / 500 mA