Secutech Radio modules ST002014 Ficha De Dados
![Secutech](https://files.manualsbrain.com/attachments/52d84a00700e00f139645836269dd00ded00d79c/common/fit/150/50/959ba6bd4311089859de31d2e4af72746569c16570aa38c73b5df4949cc8/brand_logo.gif)
Códigos do produto
ST002014
Page 18
Security & Electronic Technologies GmbH
SECU-DATA 1700M (TRbF)
Terminal Signal, function
1 Plus-pole of power supply (+22
V … +40 V),
reverse polarity protection by two 2 diodes,
igni
igni
tion prevention level “ib“
2 Ground line of power supply (0 V)
3 Connection of the positive pole of the TRbF
probe
4 Connection of the negative pole of the TRbF
probe
5 Not connected
6, 7, 8 Relay contacts, passive, for monitoring the sta-
tus of the RF-connection
7 is the root, for active RF-connection terminals
6-7 are interconnected, during RF-interruptions
terminals 7-8 are interconnected.
6-7 are interconnected, during RF-interruptions
terminals 7-8 are interconnected.
Rated switching capacity: 30 V / 500 mA