Secutech Radio modules ST002010 Ficha De Dados

Códigos do produto
ST002010
Página de 16
Security & Electronic Technologies GmbH
  
Page 3
 
 
 
 
 
 
Principle of Operation 
General 
SECU-DATA 1232 is used for wireless data transmission of RS232 signals 
(point-to-point  connections).  The  data  format  to  both  host  devices  can  be 
set individually. A hardware handshake is implemented for data flow control. 
The incoming data are prepared for the RF-transmission, a CRC-16 check-
sum  value  is  added  and  then  the  data  are  sent  to  the  remote  device.  In 
case of distortions the message is repeated automatically until it is received 
correctly by the partner instrument. Here the data are available in the preset 
format for the connected host equipment. 
The data transfer is bidirectional, the effective transfer rate is 2.400 Baud. 
 
RxD
TxD
CTS
RTS
GND
TxD
RxD
RTS
CTS
GND
RxD
TxD
CTS
RTS
GND
TxD
RxD
RTS
CTS
GND
Host device A
Host device B
SECU-DATA 1232
SECU-DATA 1232
 
 
Functionality in Detail 
 
SECU-DATA  1232  provides  a  receiver  and  a  transmitter  buffer  with  64 
bytes. RS 232 data coming in from the host device A are put into the buffer. 
If the  buffer is full or  if the  preset time-out is reached  (see section chapter 
“configuration”) line RTS blocks the data transfer and the data are sent via 
RF to the partner device which will acknowledge the reception via RF. Then 
the input buffer is cleared and RTS enables further data transfer. 
The remote SECU-DATA 1232 provides the data on the RS 232 output for 
the connected host device B.