Secutech Radio modules ST002003 Ficha De Dados

Códigos do produto
ST002003
Página de 40
Page 36
 
Security & Electronic Technologies GmbH
 
 
 
Specification of SECU-DATA 710B 
– barrier for supplying the TRbF-
probe 
Standard housing for DIN-rail mounting as per EN 50022 
Dimensions (W x D x H): 25 x 70 x 103 mm 
Material: 
 
ABS (Teluran), grey 
ATEX-parameters: 
Intrinsically safe side (ignition protection: “ia”): 
U
O
 = 23.1 V, I
O
 = 145.8 mA, C
O
 = 60 nF, L
O
 = 2 mH 
Rated specification of the active barrier SECU-BAR 125 
Standard housing for DIN-rail mounting as per EN 50022 
Dimensions (W x D x H): 25 x 70 x 103 mm 
Material: 
 
ABS (Teluran), grey 
Protection : 
 
IP20 
Ambient temperature:  -
30°C ≤ T
a
  
≤ ... +75°C 
Electrical specification: 
Nominal values:  
U
N
 = 24 V  
Input voltage:   
Range: 
18 V… 36 V DC, U
M
 = 36 V 
Output:  
 
U
O
 = 25.2 V, I
O
 = 131.3 mA,  
C
O
 = 107 nF, L
O
 = 2 mH 
 
Norms, standards applied 
ATEX  (EC-directive  94/9/EC),  EN  60079-0:2004,  EN  60079-11:2007,  EN 
61241-0:2006,  EN  61241-11:2006,  EN  60529,  ETSI  EN  300  220  (EC  di-
rective 5/1999/EG R&TTE).  
 
Connectors of SECU-DATA xxxx 
Attention: For applications in explosive areas all inputs have to be 
connected to intrinsically safe lines only.
 
The connecting wires (round cables have to be used) are fed into the hous-
ing  via  cable  glands  (M16  x  1.5,  type  SKINTOP)  with  appropriate  strain 
relief to a terminal block (type WAGO series 256). 
The  number  of  wires  and  their  functionality  depends  on  the  SECU-DATA 
model, see the appropriate section in this document. 
 
Cable glands:  
Type: SKINTOP 
Material: Body: Polyamide, halogen free, sealing: EPDM 
Dimensions: M16 x 1.5