Secutech Radio modules ST002004 Ficha De Dados

Códigos do produto
ST002004
Página de 40
Security & Electronic Technologies GmbH
 
Page 7 
 
 
mote monitoring of limit switches, of overfill prevention systems, position of 
limit  switches  etc.  in  the  chemical  industry,  in  process  automisation,  for 
loading and fuelling systems for liquids, liquid gas, and powdery products. 
SECU-DATA 500C  
RF-module  for  the  output  of  the  status  of  two  relay  contacts  sent  from  a 
SECU-
DATA  500M.  “C“  is  for  controller,  SECU-DATA  500C  is  installed  in 
the  control  centre.  In  combination  with  a  SECU-DATA  600M  (NAMUR)  or 
SECU-DATA  700M  (TRbF)  or  SECU-DATA  710M  +  SECU-DATA  710B 
tank probe conditions from NAMUR-type or TRbF-type probes can be moni-
tored remotely. 
SECU-DATA 1500C 
Same as SECU-DATA 500C but not Ex-approved 
SECU-DATA 600M  
RF-module  for  evaluation  and  transmission  of  the  output  signals  of  a  NA-
MUR 
–type probe (NAMUR is an abbreviation for: Normen Arbeitsgemein-
schaft für Mess- und Regeltechnik) as per EN 50277  to a receiver module 
SECU-DATA 500C. Intrinsically safe for the Ex-
zone 1. “M“ is for measure-
ment  site.  The  conditions  “ON“  or  “OFF”,  and  “Probe  FAULT“  are  sent  to 
the receiver SECU-DATA 500C and are indicated by two relay contacts. 
SECU-DATA 710M  
RF-module for monitoring a TRbF
–type probe (TRbF is an abbreviation for 
the  German 
Technische  Regeln  für  brennbare  Flüssigkeiten”)  with  a  re-
ceiver module  SECU-DATA  500C  for  explosive  areas
. “M“ is for measure-
ment  site.  The  conditions  “ON“  or  “OFF“,  and  “Probe  FAULT“  are  sent  to 
the  receiver  SECU-DATA  500C  and  are  indicated  by  two  relay  contacts. 
The  limit  switch  of  the  probe  is  mounted  inside  the  tank.  The  limit  switch 
monitors the filling level. It is supplied from the SECU-DATA 710M directly. 
SECU-DATA 710B  
“Classic”,  passive  diode-barrier  for  the  Ex-zone  0  for  supplying  the  limit 
switch circuitry  of a TRbF-type tank probe via an RF  module SECU-DATA 
710M. The output provides ignition protection level “ia”. 
SECU-BAR 125 
Intrinsically safe “barrier“ for the Ex-zone 1 for supplying an RF module out 
of  the  SECU-DATA  series,  if  it  is  mounted  in  the  Ex-zone  1.  The  output 
current  is limited  electronically  to 132 mA and the  output  voltage is limited 
to  max.  25.2  V,  thus  intrinsic  safety  as  per  EN  60079-11  (EN  50020)  is 
achieved. This barrier supersedes passive diode 
barriers by it’s high output 
current capability and it´s stable output voltage and is therefore best suita-
ble for universal applications.