7.Security Testing Standard(Single Cell) 
Item Battery 
Condition 
Test 
Method 
Requirements 
Crush 
Fresh, 
Full charged 
Crush between two flat plates. Applied force is 
about 13kN(1.72Mpa) for 30min. 
No explosion, 
No fire 
Short 
Circuit 
20℃ 
Fresh, 
Full charged 
Each test sample battery, in turn, is to be short- 
circuited by connecting the (+) and (-) terminals of 
the battery with a Cu wire having a maximum 
resistance load of 0.1Ω.Tests are to be conducted 
at room temperature(20±2℃ ).   
No explosion, 
No fire, 
The Temperature 
of the surface of 
the cells are 
lower than 150℃ 
Short 
Circuit 
60℃ 
Fresh, 
Full charged 
Each test sample battery, in turn, is to be short- 
circuited by connecting the (+) and (-) terminals of 
the battery with a Cu wire having a maximum 
resistance load of 0.1Ω.Tests are to be conducted 
at temperature(60±2℃ ). 
No explosion, 
No fire, 
The temperature 
of the surface of 
the cells are 
lower than 150℃
Impact 
Fresh, 
Full charged 
A 56mm diameter bar is inlayed into the bottom of 
a 10kg weight. And the weight is to be dropped 
from a height of 1m onto a sample battery and 
then the bar will be across the center of the 
sample. 
No explosion, 
No fire 
Forced 
Discharge 
Fresh, 
Full charged 
Discharge at a current of 1C
5
mA for 2.5h. 
No explosion, 
No fire 
Nail 
Pricking 
(3mm) 
Fresh, 
Full charged 
Prick through the sample battery with a nail having 
a diameter of 3mm and remain 2h. 
No explosion, 