register). This alarm glows as the BAW alarm in the GUI. As the measured 
temperature becomes greater than the BAW setting, the alarm switches off.
b) 
Above alarm window (AAW):
This alarm occurs when the measured temperature goes above the temperature 
setting performed in the alarm temperature upper boundary register (upper temp 
register). This alarm glows as the AAW alarm in the GUI. As the measured 
temperature becomes lower than the AAW setting, the alarm switches off. 
c) 
Above critical temperature (ACI):
This alarm occurs when the measured temperature goes above the temperature 
setting performed in the critical temperature register. This alarm glows as the ACI 
alarm in the GUI. As the measured temperature becomes lower than the critical 
alarm setting, the alarm switches off. 
The “Alarm” icon also glows in the GUI only when the O/P control bit is enabled in the 
configuration register and one of the above mentioned alarms has occurred, and then only 
the alarm LED onboard (D5) glows.
BAW, AAW, and ACI alarm statuses can be seen in the GUI either in Once or Loop mode. 
Pressing of the Once button shows the instantaneous alarm conditions and latches the 
same in the GUI. This condition is refreshed on again pressing the Once button. Pressing 
the Loop button continuously monitors the alarm conditions and displays them in the GUI. 
Stopping the Loop button latches the last alarm conditions in the GUI. These are refreshed 
either by again using the Once or Loop read buttons. 
For the first time address check, the default state of the upper temp register, lower temp 
register and critical temp register, is 0x00, therefore alarm conditions for AAW and ACI are 
met and so these are seen as glowing in the GUI.
Figure 7.
GUI window for STTS424E02 temperature sensor