8. Connection Options
a) Power Supply
For proper function, the 16-channel running light control must be connected to the drive battery
of a model or, in stationary operation, with a mains adapter. For this, solder two connection
lines to the left side of the board, at the solder points “UB” (+) and “GND” (-).
of a model or, in stationary operation, with a mains adapter. For this, solder two connection
lines to the left side of the board, at the solder points “UB” (+) and “GND” (-).
Figure 2
The 16-channel running light control may be used at a voltage of 5 to 18 V/DC.
In model construction practice, it has turned out to be beneficial to supply the 16-
channel running light control via the balancer plug of a 2-4-cell LiPo battery. In this
case, the power supply lines must be equipped with a suitable plug connector (like
on the balancer connection of the charger). Only the two outer plug contacts are
then used for connection.
In model construction practice, it has turned out to be beneficial to supply the 16-
channel running light control via the balancer plug of a 2-4-cell LiPo battery. In this
case, the power supply lines must be equipped with a suitable plug connector (like
on the balancer connection of the charger). Only the two outer plug contacts are
then used for connection.
5 - 18 VDC
16 - K_Lauflicht_V11
Q1
GND
UB
GND
RC
GND
TXD
RXD
SW 1 SW 2
MODE
USB TO UART
R23
C11
C10
R22
U1
U2
RESET
LED1
R21
C7
D3
R24
L1
R1
R1