35. Ventilation 
Vent holes and cooling fins are to be kept free and the required minimum distance 
must be observed. It is to be avoided that the heated up cooling air is taken in again. 
In case of installation in the open the motors are to be protected against direct 
environmental influences. 
 
 
36. Voltage and frequency
 
The motors are designed for a mains voltage of 380 - 420V, 50 Hz or 420 - 480V, 60 
Hz. Motors with an output of up to 2.2 KW inclusive are star connected and from 3.0 
KW delta connected. On request, the motors can be supplied for other voltages up to 
690V. 
 
 
 
37. Output
 
The nominal motor outputs given in the selection table are intended for constant 
operation and a mains connection at nominal voltage and nominal frequency. The 
ambient temperature may not exceed 40° C. Certain o perating conditions, such as 
ambient temperatures above 40° C or installation ab ove 1,000m above sea level as 
well as high switching rates, acceleration of large inertias etc. require separate 
inquiries and calculations.  
 
 
38. Speed 
The speeds given in the selection table are achieved at the nominal voltage, nominal 
frequency and nominal load.  
 
 
39. Protection system 
Motors are designed to the protection system IP 55 (IEC publication 34-5).  
 
 
40. Construction type and shape 
The motors can be produced in the different basic construction shapes B3 (IM1001), 
B5 (IM3001) and up to size 112 also in B14 (IM3601). The construction shapes listed 
conform to the IEC regulation 34-7.  
 
 
41. Cooling 
The motors are cooled by an external fan covered by a fan cover. Forced ventilation 
for frequency-converter duty is possible on request.