Enda ET2011-T-230 PID-CONTROLLER ET2011-T-230 Ficha De Dados

Códigos do produto
ET2011-T-230
Página de 4
5
6
SUPPLY:
NOTE :
184-253V AC
50/60Hz 5VA
Phase
Neutral
230V AC
Supply
Switch
Cable size: 1,5mm²
Fuse
F 100 mA
250V AC
Fuse should
be connected.
Order Code
2011-X XXX- X
: ET
-
Supply voltage
230
... 230V AC
24
........24V AC
VAC ...
110VAC......110V AC
0
VAC
SM.......9-30VDC/7-24V AC
Contact current selection
....
None......8A contact output
P
16A contact output
Input selection
....
RT....PT100 input
T
TC input
CONNECTION DIAGRAM
ENDA ET2011 is intended for installation in control panels. Make sure that the device is used only for intended
purpose. The shielding must be grounded on the instrument side. During an installation, all of the cables that are
connected to the device must be free of energy. The device must be protected against inadmissible humidity,
vibrations, severe soiling.Make sure that the operation temperature is not exceeded. All input and output lines
that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should
not be close to the power cables or components. The installation and electrical connections must be carried on by
a qualified staff and must be according to the relevant locally applicable regulations.
1) Mains supply cords shall meet the requirements
of IEC 60227 or IEC 60245.
2) In accordance with the safety regulations, the
power supply switch shall bring the identification of
the relevant instrument and it should be easily
accessible by the operator.
Note
Holding screw
0.4-0.5Nm
Equipment is protected throughout
by DOUBLE INSULATION.
35mm
77mm
SET
°C
SET
ET2011
ENDA
°F
C/A2
SSR
F
Flush
mounting
clamp
71mm
29,5mm
Panel cut-out
1
Flush mounting
clamp
Panel
2
73mm
5mm
Depth
Connection
cable
8
6
8
0
4
0
7
7
1
1
2
4
6
1
2
3
4
5
6
7
8
9
10
ENDA
INDUSTRIALELECTRONICS
SN:XXXXXXXXX
ET20
1-T-230
PIDDIGITAL
THERMOSTA
T
1
230VAC+10%-20%
50/60Hz5VA
11
12
C/A2
250VAC8A
RESISTIVELOAD
TC
+
-
-
+
SSROUT
MADEINTURKEY
DIMENSIONS
Note
1) Panel thickness should be maximum 7mm.
2) If there is no 60mm free space at back side of the device,
it would be difficult to remove it from the panel.
the panel:
While pressing both side of
the device in direction , push it
1
in direction 2.
For removing the device from
8 6 8 0 4 0 7 7 1 1 2 4 6
8 6 8 0 4 0 7 7 1 1 2 8 4
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
ENDA
INDUSTRIAL ELECTRONICS
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
SN: XXXXXXXXX
ET20 1-T-230
PID DIGITAL THERMOSTAT
1
ET20 1-T-230-P
PID DIGITAL THERMOSTAT
1
230V AC +10% -20%
50/60Hz 5VA
230V AC +10% -20%
50/60Hz 5VA
11
11
12
12
C/A2
250V AC 8A
RESISTIVE LOAD
C/A2
250V AC 16A
RESISTIVE LOAD
TC
TC
+
+
-
-
-
-
+
+
SSROUT
SSROUT
8 6 8 0 4 0 7 7 1 1 3 2 1
1
2
3
4
5
6
7
8
9
10
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
ET20 1-RT-230
PID DIGITAL THERMOSTAT
1
230V AC +10% -20%
50/60Hz 5VA
11 12
C/A2
250V AC 8A
RESISTIVE LOAD
-
+
SSROUT
PT100
8 6 8 0 4 0 7 7 1 1 3 6 9
PT100
1
2
3
4
5
6
7
8
9
10
ENDA
INDUSTRIAL ELECTRONICS
SN: XXXXXXXXX
ET20 1-RT-230-P
PID DIGITAL THERMOSTAT
1
230V AC +10% -20%
50/60Hz 5VA
11 12
C/A2
250V AC 16A
RESISTIVE LOAD
-
+
SSROUT
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
SURAN
Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
ET
-E
2011
4./4