6. Changing and Saving Temperature Set Value
Main Operation Screen
When SET button pressed ‘’S’’ led will
be active and temperature set value will
be displayed.
SET Value Screen
Temperature set value can
be changed with increment
and decrement buttons.
When ENTER button pressed
temperature set value can be saved.
‘’S’’ will be inactive and goes back to
main operation screen.
Main Operation Screen
Temperature set value parameter (Default=50) MODBUS ADDRESS:40001
Temperature set value, can be programmed between minimum temperature set value
and
maximum temperature set value
.
O
F
O
C
P
S
O
F
O
C
P
S
4.2 Device Label and Connection Diagram
4. Electrical Wiring Diagram
4.1 Supply Voltage Input Connection of the Device
Note-1 : External fuse is recommended.
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While
installing the unit, supply voltage range must be controlled
and appropriate supply voltage must be applied to the unit.
c
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
important in electrical connection.
External fuse that on
power supply inputs must be on
phase connection.
External fuse that on
power supply inputs must be on (+)
connection.
V
Z
c
230VCONNECTION DIAGRAM
5.Front Panel Definition and Accessing to the Menus
BUTTON DEFINITIONS
LED DEFINITIONS
1. Increment Button :
2. Decrement, Silencing Buzzer and Downloading to Prokey Button :
3. Set Button :
4. Enter Button :
7.Celcius led :
8.Fahrenheit led :
9.Set led :
10.Program led :
** It is used to increase the value in the Set screen and Programming mode.
** It is used to decrease the value in the Set screen and Programming mode.
** It is used to silence the buzzer.
** If Prc =0, it is used to download from device to prokey.
** In the main operation screen; if this button pressed, set value will be displayed. Value can be
changed using increment and decrement buttons. When Enter button pressed, value is saved
and returns back to main operating screen.
** To access the programming screen; in the main operation screen, press this button for 5
seconds.
** It is used to saving value in the Set screen and programming screen.
** Indicates that device is in C mode.
** Indicates that device is in F mode.
** Indicates that device is in Set value changing mode.
**Blinks in programming mode .
o
o
5. Cooling led :
6.Heating led :
** This led indicates that cooling control is selected and process output relay is active. If any
of compressor protection time active, this led blinks.
This led indicates that heating control is selected and process output relay is active.
**
O
F
O
C
P
S
5
6
7
7
910
1
2
3
4
8
Cooling
Heating
Sensor Offset Parameter ( Default = 0 ) MODBUS ADDRESS:40007
from -20 to 20 °C for NTC(-50°C, 100°C) or PTC(-50°C, 150°C) or J Type TC (0°C,800°C)
or J Type TC (0°C,1000°C) or PT-100(-50°C, 400°C)or PT-1000 (-50°C, 150°C) or
PT-100 (-20°C, 100°C),
from -36 to 36 °F for NTC(-58°F, 212°F) or PTC(-58°F, 302°F) or J Type TC (32°F,1472°F) or
or K Type TC (32°F,1830°F) or PT-100(-58°F, 752°F) or PT-1000(-58°F, 752°F) or
PT-100(-4°F, 212°F),
from -10.0 to 10.0°C for NTC(-50.0°C,100.0°C) or PTC(-50.0°C,150.0°C) or
PT-100 (-19.9°C,99.9°C),
from -18.0 to 18.0°F for NTC(-58.0°F,212.0°F) or PTC(-58.0°F,302.0°F) or
PT-100 (-4.0°F,212.0°F),
Compressor Start Delay at Power On Parameter ( Default = 0)
MODBUS ADDRESS:40009
When power is first applied to the device, compressor is on when this time delay is expired.
It can be adjusted from 0 to 20 minutes.
Compressor Stop-Start Delay Parameter ( Default = 0) MODBUS ADRES:40010
When compressor is inactive, this time delay must be expired for activation of the
compressor. It can be adjusted from 0 to 20 minutes.
Compressor Start-Start Delay Parameter ( Default = 0) MODBUS ADRES:40011
This time delay must be expired between two activation of the compressor. It can be
adjusted from 0 to 20 minutes.
MODBUS ADDRESS:30001
Temperature Value
MODBUS ADDRESS:30002
Led Status : 0.bit C Led,
6.bit Compressor Led,
13.bit Program Led, 14.bit Set Led
MODBUS ADDRESS:30003
Device Status :
1.bit Buzzer Status
2.bit Sensor Lost Status
MODBUS ADDRESS:30004
Output Status
MODBUS ADDRESS:30005
Device Type and Device Version
o
A
A
A
A
A
6.2 Modbus Adresses of Device Status Parameters (Read Input Register)
Operating Type Parameter ( Default = 0) MODBUS ADDRESS:40008
If parameter value is ‘0’ device skips to
parameter
5
6
9
10
12
11
8
7
1.Switch off the device.
2.Put in PROKEY then energize the device.
3.When the device is energized, the parameter values in PROKEY, start downloading to the device
automatically. At first,
message is shown on the display, when loading has finished,
message is shown.
4.After 10 seconds device starts to operate with new parameter values.
5.Remove the PROKEY.
1-Before mounting the device in your panel,
make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and make
the unit completely immobile within the panel
1-Pull mounting clamps from left and right fixing
sockets.
2-Pull the unit through the front side of the panel
Before starting to remove the unit from
panel, power off the unit and the related
system.
c
2.3 Panel Mounting
2.4 Removing from the Panel
3. Using Prokey
DOWNLOADING FROM DEVICE TO PROKEY
1.The device is programmed by using the parameters.
2.Energize the device then put in PROKEY and press
button.
Message is shown on the
display. When the loading has finished,
message is shown.
3.Press any button to turn back to main operation screen.
4.Remove the PROKEY.
DOWNLOADING FROM PROKEY TO DEVICE
NOTE:
message is shown when an error occurs while programming. If you want to reload, put
in PROKEY and press
button. If you want to quit, remove PROKEY and press
button. The
device will turn back to main operation screen.
NOTE:
message is shown when an error occurs while programming. If you want to reload,
switch off the device and put in PROKEY then energize the device. If you want to quit remove
PROKEY and press
button. The device will turn back to main operation screen.
TO USE PROKEY, VALUE OF THE PrC PARAMETER MUST BE ‘0’.
IF PrC=1 AND
BUTTON IS PRESSED
MESSAGE WILL BE SHOWN. 10s. LATER
DEVICE TURNS BACK TO THE MAIN OPERATION SCREEN OR YOU CAN PRESS SET
BUTTON TO TURN BACK TO MAIN OPERATION SCREEN.
6.1 Programming Mode Parameter List
Hysteresis Parameter for Compressor Output ( Default = 1 )
MODBUS ADDRESS:40004
from 1 to 20°C for NTC (-50°C, 100°C) or PTC (-50°C, 150°C) or J Type TC ( 0°C, 800°C ) or
K Type TC ( 0°C, 1000°C or PT-100 Type ( -50°C,400°C ) or PT-1000 Type ( -50°C,400°C )
or PT-100 Type ( -20°C,100°C ),
from 1 to 36°F for NTC (-58°F, 212°F) or PTC (-58°F, 302°F) or J Type TC (32°F,1472°F)or
K Type TC (32°F,1830°F) or PT-100 Type (-58°F,752°F) or PT-1000 Type (-58°F,752°F)
or PT-100 Type (-4°F,212°F)
from 0.1 to 10.0°C for NTC(-50.0°C,100.0°C) or PTC (-50.0°C,150.0°C)
or PT-100 (-19.9°C,99.9°C),
from 0.1 to 18.0°F for NTC (-58.0°F,212.0°F) or PTC (-58.0°F,302.0°F) or
PT-100 (-4.0°F,212.0°F),
In ON/OFF control algorithm, temperature
value is tried to keep equal to set value by
opening or closing the last control element.
ON/OFF controlled system, temperature
value oscillates continuously. Temperature
value’s oscillation period or amplitude around
set value changes according to controlled
system. For reducing oscillation period of
temperature value, a threshold zone is formed
below or around set value and this zone is
named hysteresis.
ON
OFF
Temperature
Control
Output
Set
HSt
Time
HSt
Time
Minimum Temperature Set Value Parameter (Default = Minimum Value of Device
Scale ) MODBUS ADDRESS:40005
Temperature set value can not be lower than this value.
This parameter value can be adjusted from minimum value of device scale to maximum
temperature set value parameter
Maximum Temperature Set Value Parameter (Default = Maximum Value of Device
Scale ) MODBUS ADDRESS:40006
Temperature set value can not be bigger than this value.
This parameter value can be adjusted from minimum temperature set value parameter
to maximum value of the device scale
Decimal Seperator Enabling Parameter ( Default = 0 ) MODBUS ADDRESS:40003
Disable.
Enable.
Temperature Unit Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40002
°C selected.
°F selected.
Sensor Defect Parameter ( Default = 0 ) MODBUS ADRES:40012
Compressor is active during this time period in case of probe defect (Default = 0)
MODBUS ADRES:40013
If probe defect parameter
is 2, then this parameter is observed. It can be adjusted
from 0 to 99 minutes.
Compressor is OFF in case of sensor defect.
Compressor is ON in case of sensor defect.
Compressor operates periodically according to
and
Time periods in
case of sensor defect.
Compressor is inactive during this time period in case of probe defect
( Default = 0 )MODBUS ADRES:40014
If probe defect parameter
is 2, then this parameter is observed. It can be adjusted
from 0 to 99 minutes.
Buzzer Function Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40015
Buzzer is inactive.
Buzzer is active during sensor failures.
Buzzer is active during this time
When this parameter is 1, if decrement button is pressed,
is observed. In this
condition buzzer is active till buzzer silence button is pressed.
( Default =
) MODBUS ADDRESS:40016
If buzzer function selection parameter value
=0, this parameter can not be
observed. Buzzer stays active during this time. It can be adjusted from 1 to 99 minutes
Programming Section Accessing Password
.
( Default = 0 ) MODBUS ADDRESS:40019
It is used for accessing to the programming section. It can be adjusted from 0 to 9999. If it is
selected 0, password will not be asked
PROKEY communication selected.
Communication Mode Selection Parameter ( Default = 0 ) MODBUS ADDRESS:40017
Rs485 communication selected.
Slave ID Parameter ( Default = 1 ) MODBUS ADDRESS=40018
Device communication address parameter (1 to 247).
O
F
O
C
P
S
O
F
O
C
P
S
Power Supply Connection
c
a
EXTERNAL
FUSE
(1A T)
Note-1
Supply
Switch
Supply Voltage
4
5
L
N
2
1
6
Note: If sensor input type is selected J, K, PT-100 or PT-1000 (BC =05,10,11 or 14)
parameter is
skipped.
230V
( %15) 50/60Hz ,
115V
(
%15) 50/60Hz,
24V
( %15) 50/60Hz ,
24V
( %15) 50/60Hz ,
Z
V
V
V
W
±
±
±
±
10..30 V
- 1.5 W
Must be determined in order.
Screen Blinking
Sensor failure . Sensor connection is wrong or there is no sensor connection. If buzzer function
selection parameter
is 1, internal buzzer starts to operate.
When SET button is pressed for 5
seconds, “P” led starts to blink. If
programming mode entering
password is different from 0,
programming mode entering screen
will be observed.
Main Operation Screen
Programming Screen
Change the value with increment
and decrement buttons.
Hysteresis Value for
Compressor Output
Press SET button for accessing to the parameter
value. Press increment button for accessing to the
next parameter, press decrement button for
accessing to the previous parameter.
Press OK button for saving the
parameter.
Press increment button for accessing to the
next parameter, press decrement button for
accessing to the previous parameter
Password Entering Screen
Programming Mode
Entering Screen
Press OK button for
accessing to the
password entering
screen.
Password Entering Screen
Enter programming mode accessing password
with increment and decrement buttons.
Note2: If programming mode accessing password is 0, only three parameters
are accessible, and the parameter values can be changed.
Press OK button for entering
the password.
Note1: If programming
mode accessing
password is 0,
Temperature Unit screen
is observed instead of
programming screen
Hysteresis Value for
Compressor Output
If no operation is performed in programming mode for 20 seconds, device turns to main
operation screen automatically..
i
Hysteresis Parameter
for Compressor
6.5 Entering To The Programming Mode, Changing and Saving Parameter
O
F
O
C
S
P
O
F
O
C
S
P
O
F
O
C
S
P
O
F
O
C
S
P
6.4 Failure Messages in ESM-3710-N Temperature Controller
6.3 Operation Graphics of ESM-3710-N
Controller
Temperature
O
F
O
C
S
P
O
F
O
C
S
P
O
F
O
C
P
S
O
F
O
C
S
P
1-If Operating Type Parameter Value
= 1 (Cooling),
Switch On Delay After Power On Parameter Value
1 ,
Compressor Stop/Start Time Delay Parameter Value
1 and
Compressor Start/Start Time Delay Parameter Value
1;
³
³
³
Power
Time
Hst
SET
Time
Output
Time
Time
Output
Led
°C
ON
OFF
Temperature
Value
Temperature Control Output
SET
HSt
Time
HSt
HSt
Time
2-If Operating Type Parameter Value
= 0 (Heating),
i
In ON/OFF control algorithm, temperature value is tried to keep equal
to set value by opening or closing the last control element. ON/OFF controlled system,
temperature value oscillates continuously. Temperature value’s oscillation period or
amplitude around set value changes according to controlled system. For reducing
oscillation period of temperature value, a threshold zone is formed below or around
set value and this zone is named hysteresis. Action of control output is described with
figures above.
,
,
,
,
and
Parameters are observed if Operation type
is selected “Cooling”. If operation type is selected “Heating ” ,skip to the
parameter.
i
Relay or SSR Output
2
1
4
5
6
7
P/N:
ESM-3710-N
L
N
a
Supply Voltage Input
Temperature Sensor Input
TC,NTC,PTC,PT-100
or PT-1000
230V
( %15) 50/60Hz
115V
( %15) 50/60Hz
24V
( %15) 50/60Hz
Z
V
V
V
±
±
±
10...30 V
Must be determined in order.
ü
ESM3710-N
SET
P
3
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ü
ESM3710-N
SET
P
ü
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
ü
ESM3710-N
SET
P
1
2
3
3
3
PROKEY
RS-485
or
6
7
a
16(8)A
@250V
1HP
V
L
N
2
4
5
1
NTC
L
N
16A Fuse
3
NC
NO
C
OUTPUT
INPUT SCALE
(-50
,100
;
°C
°C
°F
°F
-58 ,212
)
NTC
16(8)A @
250V
1HP
V
230 V
± 15%
50/60Hz - 1.5VA
V
P/N : ESM-3710-N - 5.18.0.1/00.00/2.3.0.0
PROKEY
RS-485
or
7
OUTPUT
NO
NC
C
LINE
LOAD
LOAD
(+)
(-)
For SSR Output
(+)
(-)