2.8 Menu bar 
 
LOGO!Soft Comfort Online Help 
106
 
Operating Instructions, 06/2014 
 
The Block column lists the parameters for SFBs in the current program. The Parameter 
column provides a select list of the parameters of the corresponding block. The Type column 
displays the data type of the selected parameter. The Address column is also configurable. 
You can use it to identify the VM address used to save a parameter value.  
The icon next to a parameter name indicates the property of this parameter: 
 
 
The parameter value is a setting value and is writable. 
 
The parameter value is an actual value and is read-only. 
 
Although the parameter value is an actual value, you can still change the value. 
NOTE: 
Only the Counter parameter of Up/Down counter has such a flag. 
 
The parameter value is referenced from an actual value of another already-
programmed function block. 
Note that if no flag appears, then the parameter value is a system value and remains read-
only. 
Within the parameter VM mapping window, you can achieve the following tasks: 
●  Select multiple record lines by pressing the Ctrl key or Shift key and clicking the ID of the 
desired line. 
●  Insert a down line by pressing the Enter key on the last cell of the desired line. 
●  Insert an up line by clicking the ID of the desired line and pressing the Insert key, or right-
clicking the desired line to add a new row. 
●  Delete a line by clicking the ID of the desired line and pressing the Delete key, or right-
clicking the desired line to delete an existing row. 
You cannot change the parameter type and must configure a unique address for each 
parameter. The range for a parameter address is from 0 to 850. If the value you input 
exceeds this range, inputs and outputs will be modified to certain VM addresses 
automatically.