5.5 UDF (0BA7 & 0BA8 only)
LOGO!Soft Comfort Online Help
Operating Instructions, 06/2014
Operating Instructions, 06/2014
353
Note
A UDF created on LOGO! Base Module 0BA8 is invalid for LOGO! Base Module 0BA7.
A UDF created on LOGO! Base Module 0BA8 is invalid for LOGO! Base Module 0BA7.
Note
Not all UDFs can be used in a circuit program. Invalid UDFs appear in the block tree, but are
Not all UDFs can be used in a circuit program. Invalid UDFs appear in the block tree, but are
gray. A UDF is invalid if it meets one or more of these conditions:
•
•
The UDF has no blocks or connectors
•
The UDF has input or output connectors, but no block connections
•
The UDF contains blocks, but no in or out connectors
A circuit program can have at most 16 different UDFs, and no more than 64 UDF instances
in total.
Within a circuit program, interaction with UDFs is consistent to other function blocks. Double-
Within a circuit program, interaction with UDFs is consistent to other function blocks. Double-
clicking, for example, produces the following dialog. With this dialog, you can set user-
defined names and comments as other function blocks.
Similarly, other blocks can reference UDF parameters, for example, you can drag the input
connector of the parameter box of a function block to the output connector of the parameter
box of a UDF block: