Secutech LC 201 Contactless Tank Liquid Level Controller Meter, With GSM Communication ST001019 ST001019 Ficha De Dados
Códigos do produto
ST001019
Security & Electronic Technologies
Seite 11
Maintenance, Troubleshooting, Service
The device does not need any maintenance.Clean the inside of the sensor cone once a year with a
dry cloth to avoid dirt and debris which could influence the beam of the ultra sonic pulses.
Make a visual check of the batteries once a year. Depending on the charge of batteries you have to
change them.
If the device shows unexpected behaviour try to reset the instrument using the Reset button.
Check your installation (look at the instructions for installation).
If the problem persists contact our service team or send the device to an authorised service facility.
If the device is damaged, remove it immediately from your tank and send it to an authorised service
facility.
If the device is removed close the tank entry after that so that the vapours can´t escape.
Technical Data
LC 200
Dimension (w x d x h):
dry cloth to avoid dirt and debris which could influence the beam of the ultra sonic pulses.
Make a visual check of the batteries once a year. Depending on the charge of batteries you have to
change them.
If the device shows unexpected behaviour try to reset the instrument using the Reset button.
Check your installation (look at the instructions for installation).
If the problem persists contact our service team or send the device to an authorised service facility.
If the device is damaged, remove it immediately from your tank and send it to an authorised service
facility.
If the device is removed close the tank entry after that so that the vapours can´t escape.
Technical Data
LC 200
Dimension (w x d x h):
130 mm x 65 mm x 160 mm
LC 200 Battery:
4 pcs. 1,5V, Baby, Type C , Alkali
Battery life time:
appr. 3 years in power safe modus at room temp.
LC 201
Power Supply
230 / 50 Hz
LC 200 / 201
Housing:
IP 65
Display:
2 line LC-Display 60 mm x 40 mm
Weight
440g
Material
ABS
Measurement range:
19 cm - 270 cm, 0 - 99.999 Liter
Accuracy:
±1 cm
Measurement intervals:
24h
Operating temperature:
-10°C ... +45°C
Engineering standards:
CE, ROHS
Threads
1 ½” and 2”
See the GTCS
– General Terms and Conditions of Sale