Arnold Rak 50 m Heating Cable / 20-6107 Ficha De Dados

Códigos do produto
20-6107
Página de 10
 
 
Important Information 
 
Please be sure to observe the following precautions when installing the heating cable: 
 
  Carefully read these instructions before commencing installation work. 
 
  When work is carried out on this heating system, this instruction must be available in accordance with 
applicable VDE regulations and handed over to the installer. 
 
  The  installation  must  be  carried  out  by  an  approved  installer  in  accordance  with  the  applicable 
standards and regulations.  
 
  Observe the specifications on the attached warranty card. The required metrics must be entered on 
the warranty card in order to validate any warranty claims. 
 
  The  manufacturer  grants  a  10-year  warranty.  This  does  not  cover  preparatory  work  such  as  fault 
finding or flooring replacement. 
 
  The  manufacturer  cannot  be  held  responsible  for  errors  that  are  attributable  to  the  omission  of  or 
erroneous measurements. 
 
  To  ensure  electrical  safety,  the  heating  cable’s  power  supply  must  be  via  a  residual  current  circuit 
breaker (RCB) with a trigger current of up to 30 mA. 
 
  To ensure that all poles of the heating system can be safely disconnected, a circuit breaker, e.g. a 2-
pole RCB with a 3 mm contact opening, must be installed. 
 
  A sign indicating the installation and configuration of the heating cable must be attached in the vicinity 
of the junction box. This sign is provided in the form of a warranty card which is supplied with every 
heating  cable  and  is  to  be  completed  with  a  location  diagram  of  the  heating  cable  –  a  sketch  is 
sufficient. 
 
  Always use a control thermostat with a floor sensor. 
 
 
 
 
 During  installation  the  heating  cable  must  be  protected  against  damage  by  falling,  sharp  or  heavy  
objects. 
 
      The heating cable must not be shortened, lengthened, folded or crossed.   
  
      Care must be taken that the heating cable cannot be stepped on during installation. 
 
      Installation across screed expansion joints is not permitted.      
      
      Do not install the heating cables in temperatures below +5° C. 
 
      Do not install the heating cable under bathtubs or shower trays or under surfaces directly covered by  
      furniture or built-in objects. 
 
      Do not start laying the floor covering prior to the functional test of the heating system. 
 
      Do not operate the heating system until the floor construction is completely dried out.