Vision Akkus VISION CP12150D, 12V Ah lead acid battery CP12150D CP12150D Ficha De Dados
Códigos do produto
CP12150D
CP12150D
12V 15Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid
electrolyte is absorbed by separators and plates and thus immobilized. Should the
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up.
Otherwise, the battery is completely sealed and is, therefore, maintenance-free,
leak proof and usable in any position.
Battery Construction
Component
Positive plate
Negative plate
Container Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
Fiberglass
Sulfuric acid
General Features
●
Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
●
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
●
UL-recognized component.
●
Can be mounted in any orientation.
●
Computer designed lead, calcium tin alloy
grid for high power density.
●
Long service life, float or cyclic
applications.
●
Maintenance-free operation.
●
Low self discharge.
Dimensions and Weight
Length(mm / inch)
151 / 5.94
Width(mm / inch)
98 / 3.86
Height(mm / inch)
95 / 3.74
Total Height(mm / inch)
101 / 3.98
Approx. Weight(Kg / lbs)
4.4 / 9.7
Performance Characteristics
Nominal Voltage
12V
Number of cell
6
Design Life
3~5 years
Nominal Capacity 77
o
F(25
o
C)
20 hour rate (0.75A, 10.5V)
15Ah
10 hour rate (1.3A, 10.5V)
13Ah
5 hour rate (2.5A, 10.5V)
12.5Ah
1 hour rate (10.5A, 9.6V) 10.5Ah
Internal Resistance
Fully Charged battery 77
o
F(25
o
C)
16mOhms
Self-Discharge
3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
Discharge
-20~60
o
C
Charge
-10~60
o
C
Storage
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C)
180A(5s)
Short Circuit Current
600A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C)
Cycle use
14.5-14.9V
Maximum charging current
4.8A
Temperature compensation
-30mV/
o
C
Standby use
13.6-13.8V
Temperature compensation
-20mV/
o
C
Discharge Constant Current (Amperes at 77
o
F25
o
C)
End Point
Volts/Cell 5min 10min 15min 30min 1h
3h
5h
10h 20h
1.60V
54.0 37.5 27.0 16.0 9.28 3.50 2.20 1.20 0.61
1.65V
52.1 36.3 26.7 15.7 9.17 3.47 2.19 1.20 0.61
1.70V
50.5 35.3 26.1 15.4 9.06 3.43 2.17 1.19 0.61
1.75V
48.8 34.2 25.5 15.1 8.94 3.40 2.15 1.18 0.60
1.80V
47.1 33.3 24.9 14.7 8.84 3.37 2.12 1.16 0.59
Discharge Constant Power (Watts at 77
o
F25
o
C)
End Point
Volts/Cell 5min 10min 15min 30min 45min 1h
2h
3h
5h
1.60V
105 71.6 56.0 32.4 23.3 18.4 9.69 7.28 4.62
1.65V
102 70.4 55.2 31.9 22.9 18.2 9.59 7.21 4.59
1.70V
99.1 69.1 54.4 31.4 22.5 18.0 9.50 7.13 4.55
1.75V
96.5 67.8 53.5 31.0 22.1 17.8 9.40 7.06 4.52
1.80V
93.9 66.6 52.7 30.5 21.7 17.7 9.30 6.99 4.49
page1 of 2
www.vision-batt.com
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.