Idec Handle switch 250 Vac 3 A IP65 momentary 1 pc(s) HE1G-21SMB Ficha De Dados
Códigos do produto
HE1G-21SMB
HE1G Series
Enabling Switches
416
www.idec.com
Overview
X Series E-Stops
Door Interlock Switches
Enabling Switches
Barrires
AS-Interface Safety at W
ork
HE1G Series Grip Style Enabling Switch
HE5B Key features include:
3 position funtionality (Off – On – Off) as required for manual robotic control
Ideally suited for use as an enabling (aka “deadman”) switch for robotic cells
Provides a high level of safety based on human behavioral studies that determine
personnel may squeeze OR let go when presented with a panic situation
Contacts will not re-close when released from Off ‡ On (3 ‡ 1) (per IEC60204-1; 9.2.5.8)
Optional E-Stop switch built in
Connection for conduit and cable strain relief built in
IP66 waterproof sealing
Meets ANSI RIA 15.06 robotics standards
Optional momentary pushbutton or E-Stop built in
Ideally suited for use as an enabling (aka “deadman”) switch for robotic cells
Provides a high level of safety based on human behavioral studies that determine
personnel may squeeze OR let go when presented with a panic situation
Contacts will not re-close when released from Off ‡ On (3 ‡ 1) (per IEC60204-1; 9.2.5.8)
Optional E-Stop switch built in
Connection for conduit and cable strain relief built in
IP66 waterproof sealing
Meets ANSI RIA 15.06 robotics standards
Optional momentary pushbutton or E-Stop built in
GS-ET-15
BG standard in Germany
BG standard in Germany
Direct Opening
Action
Double
Installation
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Specifi cations
Conforming to Standards
IEC60947-5-1, EN60947-5-1, JIS C8201-5-1, UL508, CSA C22.2 No 14
Applicable Standards
ISO12100/EN292, IEC60204-1/EN60204-1, ISO11161/prEN11161, ISO10218/EN775, ANSI/RIA R15.06,
Operating Temperature
–25 to +60˚C (no freezing)
Operating Humidity
45 to 85% RH maximum (no condensation)
Storage Temperature
–40 to +80˚C (no freezing)
Pollution Degree
3
Contact Resistance
100mΩ maximum
Insulation Resistance
Between live & dead metal parts: 100MΩ maximum
Between positive & negative live parts: 100MΩ minimum
Between positive & negative live parts: 100MΩ minimum
Impulse Withstand Voltage
2.5kV
Operating Frequency
1200 operations/hour
Mechanical Life
Position 1‡ 2‡ 1: 1,000,000 operations minimum
Position 1‡ 2‡ 3‡ 1: 100,000 operations minimum
Electrical Life
100,000 minimum at rated load
Shock
Resistance
Resistance
Operating Extremes
100m/s
2
(10 G)
Damage Limits
1000m/s
2
(100 G)
Vibration
Resistance
Resistance
Operating Extremes
5 to 55Hz, amplitude 0.5mm minimum
Damage Limits
16.7Hz, amplitude 1.5mm minimum
Recommend Wire Size
0.14 to 1.5mm
2
(24AWG - 16AWG)
Recommend Cable Size
ø7 to 13mm
Conduit Size
M20
Terminal Pulling Strength
20N minimum
Terminal Screw Torque
0.5 to 0.6Nm
Degree of Protection
HE1G-21SM: IP66, HE1G-20MB: IP65
HE1G-20ME: IP65, HE1G-21SMB: IP65
Conditional Short Circuit Current
50A (250V)
Recommended Short Circuit Protection
250V/10A fast blow fuse (IEC 60127-1)
Weight
Approx. 250g (HE1G-20ME)
Approx. 210g (HE1G-21SM)
Approx. 210g (HE1G-21SM)