124 Program description: Telemetry menu
MODEL SELECT
Select the desired menu line „MODEL SELECT“ using
the
Select the desired menu line „MODEL SELECT“ using
the
INC
button.
Now press
ENTER
…
CAR
AIRPLANE,HELI.,GLID.
and again
ENTER
...
RECEIVE
RECEIVE+GENERAL/GAS
RECEIVE+ELECTRONIC
RECEIVE+VARIO
RECEIVE+GPS
RECEIVE+ELECTRONIC
RECEIVE+VARIO
RECEIVE+GPS
… press the
INC
-
button to choose the sensor with the
arrow and fi nally press
ENTER
to select:
RX–S QUA: 100%
RX–S ST : 100%
RX–S ST : 100%
TX–dBm: 33dBm
RX–dBm: 33dBm
RX–VOLT:4.8 TMP
V–PACK: 10ms
CH OUTPUT TYPE:ONCE
M–RX V :4.6 +22°C
DATA VIEW
RECEIVER
RX–S QUA: 100%
RX–S ST : 100%
RX–S ST : 100%
TX–dBm: 33dBm
RX–dBm: 33dBm
RX–VOLT:4.8 TMP
V–PACK: 10ms
CH OUTPUT TYPE:ONCE
M–RX V :4.6 +22°C
This screen displays the data which can also be viewed
in the “RX DATAVIEW” screen of the telemetry menu
“SETTING & DATA VIEW”, but in graphic form.
The meanings are as follows:
in the “RX DATAVIEW” screen of the telemetry menu
“SETTING & DATA VIEW”, but in graphic form.
The meanings are as follows:
Value
Explanation
RX-S QUA
Signal quality in %
RX-S ST
Signal strength in %
RX-dBm
Receive performance in dBm
TX-dBm
Transmit power in dBm
V PACK
shows the longest period in ms in
which data packets were lost in
transmission from transmitter to
receiver
which data packets were lost in
transmission from transmitter to
receiver
RX-VOLT
Current receiver operating voltage in
Volt
Volt
M-RX V
Lowest receiver operating voltage in
Volt since the last time it was switched
on
Volt since the last time it was switched
on
TMP
The thermometer indicates the
receiver’s current operating
temperature
receiver’s current operating
temperature
Just like described in the menu „MODEL SELECT“ ...
RECEIVE
RECEIVE+GENERAL/GAS
RECEIVE+ELECTRONIC
RECEIVE+VARIO
RECEIVE+GPS
RECEIVE+ELECTRONIC
RECEIVE+VARIO
RECEIVE+GPS
...the output can be selected to graphically processed
data from a sensor connected to the receiver if
necessary. These data are then presented according to
the following graphic displays.
Scroll back and forth between the different graphic
displays with the
data from a sensor connected to the receiver if
necessary. These data are then presented according to
the following graphic displays.
Scroll back and forth between the different graphic
displays with the
INC
or
DEC
key and choose by
pressing
ENTER
, press
ESC
to return back to the basic
display.
Note:
The order of displays described below follows the
sequence when pressing the
The order of displays described below follows the
sequence when pressing the
INC
button.
More details about the following modules can be found
in the appendix and on the internet at www.graupner.de
for the relevant product.
in the appendix and on the internet at www.graupner.de
for the relevant product.