Emag Emmi-5P ultrasound cleaner 0.5 l 175 x 80 x 40 mm EMMI 5P EMMI 5P Ficha De Dados

Códigos do produto
EMMI 5P
Página de 2
1. GERäTEbESchREIbuNG
1. Time adjustment 1 -9 minutes
2. Removable tank
3. Reset
4. Digital time indication 
2
1
3
4
2
3
Parameter
Inner tank dimensions 
Length (mm)
175
Width (mm)
80
Height (mm)
40
Dimensions
Length (mm)
190
Width (mm)
100
Height (mm)
124
Power supply
230V~/ 50 Hz
Protection class
IP 20
Power
max. 50
 
Technical changes reserved.
2. TEchNIcAl DATA
 
3. cONvENTIONAl uSE
The equipment may only be used for the purpose as set forth in the catalogue and in the techni-
cal descriptions which means for ultrasonic cleaning as described in this instruction, and only 
in conjunction with external devices and components which are recommended or approved by 
EMAG AG. Any other use of the equipment is considered to be non conventional. 1In case of non 
conventional use, EMAG AG will not be liable for possible damages and will not warrant for the 
correct and functional work of the components. Part of the conventional use is also the obser-
vance of all information given in the operating manual. To this attention is drawn by the sign on 
the type plate. The correct and safe operation of the equipment implies appropriate transportation, 
storage, installation and assembly as well as careful handling and maintenance.
4. NON cONvENTIONAl uSE
In case of non conventional use of the equipment danger for life and limb as well as danger for 
property may occur. Therefore a non conventional use is prohibited. In case of non conventional use 
EMAG AG will not be liable for possible damages and will not warrant for the correct and functionally 
work of the components. In order to avoid non conventional use of the ultrasound cleaning equip-
ment the following directions are to be considered:
•  The equipment may only be operated with the voltage printed on the type plate on the backside/ 
bottom side of the housing (shockproof socket).
•  No flammable or aggressive chemicals (i.e. acids etc.) must be  used for operation of the equip-
ment. If necessary, use glass container EM 50 DG.
•  During operation do not touch the liquid.
•  In case of transportation damage, don`t connect the equipment with main source.
•  Do not clean creatures (i.e. finger nails, animals etc.) in the equipment.
•  The equipment must only be operated with the correct level of water (water till mark, approx. 1 cm 
below upper brim). This must be controlled if equipment is operated for a longer time.
•  Strongly contaminated goods shall be positioned in the equipment with the contaminated side to 
the bottom – do not staple goods.
•  The goods to be cleaned must not be positioned directly onto the bottom of the tub – use the basket.
•  If the equipment is operated for a longer time, do not stay longer than 4 hours within 1 m distance 
to the equipment.
•  The equipment must only be operated indoor and within a dry environment.
•  It is normal, that the upper brims warm up at longer operation.
5. OPERATING INSTRucTION
The tub is filled with water – with or without cleaning concentrate – and the power connector is 
connected with main source. After power switch is ON cleaning time can be adjusted by the push 
button. By pressing the timer button  cleaning time can be set to wished duration. Permanent opera-
tion should be avoided because by evaporation of the water the equipment may run dry and may be 
damaged. In no case a permanent operation time of 4 hours must be exceeded. The cleaning time to 
be adjusted depends on the contamination level of the goods to be cleaned. If the adjusted cleaning 
time is terminated, the equipment automatically stops the cleaning operation. If start button is again 
pressed the equipment starts again to operate. For stopping equipment operation use RESET switch. 
After termination of the cleaning operation remove cleaned goods from equipment and rinse under 
running water in order to remove possibly still adhered particles. After termination of a cleaning op-
eration – or several cleaning operations – it is recommended – depending on the degree of contami-
nation – to exchange the water. The tub shall be rinsed and dried by a cloth. Please make sure, that 
equipment is operated on dry ground and that no water can penetrate through the slots in the bottom 
of the lower part of the equipment into the equipment.
Advise:
If equipment is filled with new water, please consider a reasonable time for
the outgazing of the water (best cleaning efficiency is achieved with outgazed
water). We recommend an operation of the equipment with water for a couple
of minutes before you insert the goods for cleaning.
6.ExAMPlES fOR ThE clEANING Of GOODS WITh ulTRASOuND
• Eyeglasses, glass frames (please pay attention: Glasses must not be in
  direct contact with the tub bottom).
• Gold and silver jewels, jewelery, emeralds, pearls
• Ink crayons, drawing instruments / - accessories
• Dentures, braces, and many more.