3com H3C® RPS 800 0213A02R-ME Ficha De Dados

Códigos do produto
0213A02R-ME
Página de 4
3COM
®
H3C REDUNDANT POWER SYSTEMS
3
POWER
Max. output power with two power
rectifiers: 2900 Watt
Input power
AC line frequency: 50/60 Hz
AC input voltage: 100-120/200-240 VAC
Current rating (one system): 6/8 A
Output power
with 1 power rectifier
Input Voltage
Output Power
100 VAC to 120 VAC
600 Watt
200 VAC to 240 VAC
1450 Watt
with 2 power rectifiers
Input voltage
Output Power
100 VAC to 120 VAC
1200 Watt
200 VAC to 240 VAC
2900 Watt
Output voltage/current
Two output connections: -53 to -55
Volts, 25 Amp
Six output connections: -53 to -55
Volts, 8 Amp
Output dynamic response: -54
VDC±2%.
Static regulation: -54 VDC±1%.
DIMENSIONS
RPS 1000
Height: 44.5 mm (1.7 in or 1 RU)
Width: 440.0 mm (17.4 in)
Depth: 393.0 mm (15.5 in)
Weight: <8kg (17.6 lb)
Power Rectifier Unit
Weight: 2.8kg (6.17 lb)
RELIABILITY
Mean Time Between Failure (MTBF):
420,000 hours (47.9 years)
ENVIRONMENTAL
Operating temperature: 5° to 45°C
(41° to 113°F)
Storage temperature: 40° to 70°C
(104° to 158°F)
(allow 4+ hours after low temperature
storage before operating)
Humidity (operating and storage):
5% to 90% non-condensing
PACKAGE CONTENTS
RPS 1000 Unit
RPS 1000 unit with one installed
power rectifier and one blanking plate
one power cord
one Cable A with JD5 type connector
(0404A053)
three cables with JD5-A type
connector (0404A054)
one Cable B with JD5 type connector
(0404A055)
front and rear mounting brackets
rubber feet for desktop setup
six backup fuses 10A/125V
grounding cable
mini-screwdriver for releasing
mounting clips
user manual
Power Rectifier Unit
Power rectifier unit
(label: AC-Flatpack 1500-M)
One power cord
One Cable A with JD5 type connector
(0404A053)
Three cables with JD5-A type
connector (0404A054)
One Cable B with JD5 type connector
(0404A055)
One mini-screwdriver for releasing
mounting clips
NOTE
When the RPS 1000 is used with a
switch, the RPS takes the full power
load. Therefore, the RPS 1000 must have
enough power to provision the switch and
all Power over Ethernet requirements.
The RPS 1000 does support giving
power to multiple devices provided the
connections are present and there is
adequate power for the various devices.
Consider all the power requirements—
both for the switch or switches
themselves, together with any PoE
connections—to ensure that the RPS
1000 has sufficient Watts of output to
power the attached switches.
SPECIFICATIONS
The H3C RPS 800 is an external DC power supply unit that uses AC input and provides DC output for switch
redundant backup power.
This 1RU RPS provides selective DC outputs. Depending on the connected DC output cable(s), the RPS can
provide +12 VDC, –54 VDC, or +12 VDC and –54 VDC concurrently, to the powered device. The RPS 800
supports cold backup of power supply, which means that the RPS 800 only switches to the DC output state
when it detects a power supply failure of the powered device.
Use with:
3Com Switch 4800G 48-port
H3C S5500-52C-EI
RPS 800:
FEATURES
POWER
Max. output power
+12 V output only: 210 W
-54 V output only: 650 W
+12 V and – 54 V output:
210 W for +12 V output
440 W for -54 V output
Total: < 650 W
Input power
AC Line Frequency: 50/60 Hz
AC input voltage: 110-240 VAC
Available outputs
-54 V / 12 A
+12 V / 17.25 A
DIMENSIONS
Height: 44 mm (1.7 in or 1 RU)
Width: 441 mm (17.4 in)
Depth: 182 mm (7.2 in)
Weight: <3.8kg (8.4 lb)
ENVIRONMENTAL
Operating temperature:
0° to 45°C (32° to 113°F)
Operating humidity:
10% to 90% non-condensing
PACKAGE CONTENTS
RPS 800 unit
Power cord
Front and rear mounting brackets
SPECIFICATIONS
See table, page 2 for 3Com switch models
supporting an RPS connection.
See table, page 2, for 3Com switch models
supporting an RPS connection.
The H3C RPS 1000 is an external power supply unit that uses AC inputs and provides eight lines of DC output,
with a maximum output power of 2900 W. Protection is built-in against input and output high voltage and
short-circuits. Indicator lights show output current status.
This RPS is 1U high; two power rectifiers can be installed for 1+1 load sharing and power redundancy. It
supports switches with -54V RPS connections, with sufficient power for Power over Ethernet redundancy.
Use with:
3Com Switches 5500G, 4800G PWR, 4500G PWR, 4200G PWR, 5500, 4500 PWR, 4200 PWR
H3C Switches S5600, S5500 PWR, S5100-EI, S3600-EI
RPS 1000:
FEATURES
Available Cables for the RPS 1000
CABLE TYPE
DETAILS
Cable A, JD5 connector
(0404A053)
For use with PoE (PWR) units; 25A max output current
Cable, JD5-A connector
(0404A054)
For use with non-PoE units; 8A max output current
Cable B, JD5 connector
(0404A055)
For use with non-PoE units; 8A max output current
Available Cables for the RPS 800
CABLE TYPE
DETAILS
0404A08G
Cable G — RPS power cable 1 meter