Eurolite N-110 silver with ON/OFF controller 51701965 Ficha De Dados

Códigos do produto
51701965
Página de 31
51701965_V_1_1.DOC
16/31
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
OPERATION
Switch the device on via the power switch. Connect the remote control with the Remote Control-socket.
The stand-by lamp of the remote control lights up. After a warm-up time the stand-by lamp turns off and the
device is ready for operation. While pressing the remote control button, the smoke emission starts and the
control lamp lights up again. If the remote control button is released before the machine stops emitting fog,
then the lamp will be off. If the remote control button is released after the machine stops emitting fog, then
the lamp will be on continuously. In either case, upon reaching a certain temperature the machine will begin
reheating and the stand-by lamp of the remote control lights up (or remains lit). The temperature is regulated
by a high quality thermostat. This process guarantees an appropriate vaporization temperature and the best
smoke emission possible. When the stand-by lamp turns off, then the device is ready for operation again.
CAUTION: The escape nozzle will heat up during operation. Therefore do not touch the nozzle until it
has cooled down completely.
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues.
Cleaning the heating element
The heating element should regularly be cleaned every 30 operational hours in order to avoid clogging. Use
smoke machine cleaner available at your dealer.
Procedure:
Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repititions depends on the pollution level of the vaporizing elements. After use clean all remaining cleaner
and rinse the tank thoroughly.