Beg Brueck B.E.G. Brück White IP44 91052 Ficha De Dados

Códigos do produto
91052
Página de 2
LUXOMAT
®
 LC-Mini 120 / 180
GB
Installation and Operation Instruction motion detector B.E.G. – LUXOMAT
®
 LC-Mini 120 and LC-Mini 180
1. Mounting preparations
1)  
Caution: have all work involving the 
230 V mains supply carried out by a 
qualified electrician! Before starting 
disconnect the mains! Please be aware, 
that the LUXOMAT
®
 LC-Mini 120/180 is 
not suitable as an intrusion detector, since 
it is not equipped with a tamper contact.
2)  Socket base corner mounting
Important: The LUXOMAT
®
 LC-Mini 
120/180 has to be mounted in such a way, 
that the adjusting elements / rotary regulators 
are always pointed downward.
1
2. Mounting types
1)  Wall mounting
1
4. Inserting of the connection cable
1) Connection cable from top down
2) Terminal markings
8. Putting into operation / Settings
Follow-up time
4 sec. ...10 min.
Lux value
Night operation...Dusk...Day operation
(Day operation: light sensor inactive, switching 
at any brightness value)
Self test cycle
After mounting and connecting the 230 VAC supply 
voltage, the detector pass a self-test. Afterwards the 
settings can be made manually.
3. Plug-in socket
Mount the plug-in socket with two screws and
the enclosed seal rings on a firm base.
(Pay attention to inserting of the connection
cable, see point 4)
5. Sensor head optics
By swinging the sensor head horizontally 
(ca. ±45°) and vertically (ca. ±15°) the 
detection area can be changed.
2
6. Connection
7. Exclude sources of interference
9. Range of Coverage
walking towards
walking across
1
2
walking towards
walking across
1
2
1)  If possible mount unit on a safe place 
(wall or ceiling mount) 
10. Mounting place
1
2
2)  Influence of weather reduces the lifetime of 
the unit. Please take care to mount correctly. 
3
> 1m
4
3)  Minimum distance to switched lighting, 
frontally or laterally to device: 1 m 
4)  Never mount the connected lights below the 
motion detector!
If necessary, the lens segment(s) corresponds to 
unwanted detection zones may be masked with 
the enclosed covers to reduce the fi eld of vision.
L
N
L’
L
N
L’
Cover
L
N
L’
4
sec
20
50
1.2
10
min
6
4
sec
20
50
1.2
10
min
6
7 m
4 m
10 m
180°
2,50 m
2
1
7 m
4 m
10 m
120°
2,50 m
2
1
2 Lux
20
40
260
2000
2 Lux
20
40
260
2000