Woodstock M1109 Manual Do Utilizador

Página de 74
-42-
M1109 Combo Lathe/Mill
SE
RV
IC
E
SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
Entire machine 
vibrates exces-
sively upon 
startup and while 
running.
1.  Workpiece is unbalanced.
2.  Worn or broken gear present.
3.  Chuck or faceplate has become unbalanced.
4.  Spindle bearings badly worn.
1.  Reinstall  workpiece  so  it  is  as  centered  with  the 
spindle bore as possible.
2.  Inspect gears and replace if necessary.
3.  Rebalance  chuck  or  faceplate;  contact  a  local 
machine shop for help.
4.  Replace spindle bearings.
Bad surface fin-
ish.
1.  Wrong RPM or feed rate.
2.  Dull tooling or poor tool selection.
3.  Too much play in gibs.
4.  Tool too high.
1.  Adjust for appropriate RPM and feed rate.
2.  Sharpen  tooling  or  select  a  better  tool  for  the 
intended operation.
3.  Tighten gibs.
4.  Lower the tool position.
Can't remove 
tapered tool 
from tailstock 
quill.
1.  Quill had not retracted all the way back into 
the tailstock.
2.  Debris  was  not  removed  from  taper  before 
inserting into quill.
1.  Turn the quill handwheel until it forces taper out 
of quill.
2.  Always make sure that taper surfaces are clean.
Cross slide, com-
pound slide, or 
carriage feed has 
sloppy operation.
1.  Gibs are out of adjustment.
2.  Handwheel is loose.
3.  Lead screw mechanism worn or out of adjust-
ment.
1.  Tighten gib screw(s).
2.  Tighten handwheel fasteners.
3.  Tighten any loose fasteners on lead screw mecha-
nism.
Cross slide, com-
pound slide, or 
carriage feed 
handwheel is 
hard to move.
1.  Gibs  are  loaded  up  with  shavings,  dust,  or 
grime.
2.  Gib screws are too tight.
3.  Backlash setting too tight (cross slide only).
4.  Bedways are dry.
1.  Remove gibs, clean ways/dovetails, lubricate, and 
readjust gibs.
2.  Loosen  gib  screw(s)  slightly,  and  lubricate 
bedways.
3.  Slightly  loosen  backlash  setting  by  loosening  the 
locking screw and adjusting the spanner ring at the 
end of the handle.
4.  Lubricate bedways and handles.
Cutting tool or 
machine com-
ponents vibrate 
excessively dur-
ing cutting.
1.  Tool holder not tight enough.
2.  Cutting tool sticks too far out of tool holder; 
lack of support.
3.  Gibs are out of adjustment.
4.  Dull cutting tool.
5.  Incorrect spindle speed or feed rate.
1.  Check for debris, clean, and retighten.
2.  Reinstall  cutting  tool  so  no  more  than  1/3  of  the 
total length is sticking out of tool holder.
3.  Tighten gib screws at affected component.
4.  Replace or resharpen cutting tool.
5.  Use the recommended spindle speed.
Inaccurate turn-
ing results from 
one end of the 
workpiece to the 
other.
1.  Headstock  and  tailstock  are  not  properly 
aligned with each other.
1.  Realign the tailstock to the headstock spindle bore 
center line.
Chuck jaws won't 
move or don't 
move easily.
1.  Chips lodged in the jaws.
1.  Remove  jaws,  clean  and  lubricate  chuck  threads, 
and replace jaws.
Carriage won't 
feed.
1.  Gears are not all engaged.
2.  Gears are broken.
3.  Loose screw on the feed handle. 
1.  Adjust gear positions.
2.  Replace.
3.  Tighten.
Operation and Work Results