Terminate Premise Wiring: 
Direct Distribution 
Run twisted pair cable from the telephone jacks throughout the premise to the 
numbered distribution jacks.  Terminate modular 8 position plugs to the horizontal 
cables using the 568A wire standard.   
   
Patch Panel Distribution 
Run twisted pair cable from the telephone jacks throughout the premise to the 110 
IDCs of a SAM-D8 patch panel using the termination procedure above.  Connect 
the numbered distribution ports of the SAM-V8M to the desired ports of the 
SAM-D8 patch panel with 8 conductor patch cords. 
 
Note: The 3” jumper cord must be plugged into the “OUT” & “TEST” ports to provide service to 
premise wiring. 
 
Alarm Interface Connection: 
The SAM-V8M features a security interface port which may be connected to a security 
system; in an emergency situation, the security system can seize telephone service on 
LINE 1 when the alarm is activated.  Connect 8 conductor cord from alarm dialer to the 
“Security RJ31” port on the SAM-V8M