FACTORY SETTINGS 
(for each dispense head)
• Tank temperature is set at 200 degrees F.
• Brew time is pre-set at 2:20. (Volume/time to be set on-site)
• Pulse Brew is set for 1 pulse, 20 sec on, 20 sec off.
• Warmer Energy Savings mode is set for 60-minutes. (“OFF” for models without warmers)
• Low Temp / No Brew option is set to “OFF” or disabled.
• Pour over setting override is set to “no” or plumb in.
• Settings lock-out jumper on controller is set in “unlock” position.
ADJUSTMENTS:  
Refer to B-Series Programming Chart on page 5.
NOTE: 
Set each dispense head individually o
n two head models with two controllers and serial numbers A166225 and 
lower (without a -P suffix). Tank temperature must be set to the same setting on both heads in order for the unit to 
operate properly. 
Tank Temperature:
Left display controls this.
• Press-and-hold both “up” and “down” arrows for 5 seconds. 
• The display will indicate either “d  F” or “d  C”. (Fahrenheit or Celsius)
• Press up or down arrow to change from one scale to the other.
• Press “BREW” button to accept and proceed to the next setting. 
• The display will read temperature value in the scale previously selected.
• Press up or down arrow to change temperature value. 
• Press “BREW” button to accept and proceed to the next setting. 
Brew Time:
• The display will read “br ”.  (brew time)
• Press “BREW” button to proceed to the next setting. 
• The display will read the set brew time in minutes and seconds. (ex: 2.20)
• Press up or down arrow to change time value. 
• Press “BREW” button to accept and proceed to the next setting. 
Pulse Brewing Mode:
• The display will read “P-b”. (pulse brew)
• Press “BREW” button to proceed to the next setting. 
• The display will read “OFF” - “1”- ”6”. 
• Press up or down arrow to change number of pulses. 
• Press “BREW” button to proceed to the next setting.
• The display will read “0.05” - “0.30”.
• Press up or down arrow to change pulse-on time for each pulse in seconds.
• Press “BREW” button to proceed to next setting.
• The display will read “0.05” - “0.30”.
• Press up or down arrow to change pulse-off time for each pulse.
• Press “BREW” button to accept and proceed to the next setting. 
Energy Savings Mode (Warmer shut-off):
• The display will read “E-S”.  (energy savings)
• Press “BREW” button to proceed to the next setting. 
• The display will read “Off” - “10” - “240” in multiples of 10. 
• Press up or down arrow to change time value in minutes.  Must be “OFF” for models without warmers.  
• Press “BREW” button to accept and proceed to the next setting. 
Low Temp/No Brew Mode:
• The display will read “Ltn” (Low Temp/No Brew).
• Press “BREW” button to proceed to the next setting.
• Press up or down arrow to change to “ON” or “OFF”.
• Press “BREW” to accept and proceed to the next setting.