Dyson Airblade Tap Manual Do Proprietário

Página de 12
3
WARNING:
This unit contains substances known to the state of California to cause cancer, 
birth defects and other reproductive harm. Wash hand after installation or repair 
of this unit.
READ AND SAVE THESE INSTRUCTIONS
LOOkING AfTER yOUR HAND DRyER
WARNING
This product is not to be used in sinks where a plug is fitted. Before engaging the water 
flow ensure that the plughole is clear of any obstructions and that water can drain freely.
HOW TO USE
1. Place your hands beneath the center of the tap and water will flow automatically for as long 
as the hands remain in place.
2. Place your hands to either side of the center tap to activate the hand dryer, creating sheets of 
air to scrape water from your hands.
3. Move your hands backwards and forwards slowly through the air, turning them over so both 
back and front are exposed to the airflow.
TROUBLESHOOTING GUIDE
WARNING: RISk Of ELECTRIC SHOCk.
Problem
Action
The hand dryer fails to start.
Check fuse/circuit breaker is working and that the 
power and water supply are connected. Must be 
performed by a qualified electrician.
Ensure the cleaning cap is removed and that the 
sensors are clean and unobstructed.
If a safe method of switching is available, turn the 
unit on and off. If a safe method is not available, a 
qualified electrician must perform this task.
The hand dryer is turning on and 
off erratically.
Ensure sensors are clean.
Check that the sensor cable from the tap is securely 
connected. Must be performed by a qualified 
electrician.
The hand dryer sometimes cuts out 
when in use but resumes operation 
after a period of time.
Check the air inlet is clean and free of dust.
If the air inlet is dusty simply remove dust.
Ensure that the air inlet is free from obstructions and 
has sufficient clearance (see installation instructions).
The dry time of the hand dryer has 
increased.
The air flow from the hand dryer is 
running hotter than usual.
Inspect the inlet grille for dust and remove. Inspect 
filter and change if required.
Ensure that the hose is securely attached to the base of 
the tap and no leaks are present. Must be performed 
by a qualified electrician.
Air is continuously running from the 
hand dryer.
Ensure sensors are clean and free from any 
obstructions