Beck, R&J ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESSCONTROL 11-1_9 Manual Do Utilizador
34
DCM-2 HART INTERFACE
Communication
* THIS VALUE CAN BE EDITED
** INDICATES AN ACTION RATHER THAN THE VIEWING OR EDITING
OF A PARAMETER
OF A PARAMETER
THIS IS THE MENU DISPLAYED BY THE HART COMMUNICATOR
AT POWER UP IF COMMUNICATION IS ESTABLISHED
THIS AND OTHER OFFLINE MENUS ARE COMMON TO ALL
HART COMMUNICATOR APPLICATIONS - MANY SUBMENUS EXIST
(1)
(2)
1
BLOCK REFERENCE NUMBERS APPEAR AT THE
UPPER RIGHT CORNER OF EACH BLOCK.
UPPER RIGHT CORNER OF EACH BLOCK.
Online
(1)
1 Functions
2 Position
2 Position
45.4%
3 Demand
45.4%
4 Loop(Dem)
11.29 mA
5 Trq/Thrust
3%
6 Temp
73 degF
7 Feedback
11.30 mA
2
Functions
1 Setup Checklist
2 Device Information
3 Configuration
4 Statistics
5 Manual Operation
6 Diagnostics
7 Calibration Trim
1 Setup Checklist
2 Device Information
3 Configuration
4 Statistics
5 Manual Operation
6 Diagnostics
7 Calibration Trim
3A
Setup Checklist
1 Drive S/N*
2 Drive Dir*
1 Drive S/N*
2 Drive Dir*
CW Incr
3 Feedback*
Enabled
4 CPS Zero%*
1.000 v
5 PositionUnit*
deg
6 MaxTravel*
100 deg
7 Travel*
100 deg
8 DemRngLwr*
4.00 mA
9 DemRngUpr*
20.00 mA
Dem
Curve*
Linear
•
•
•
Alarm
Mask
0xffffffff
4B
General Setup
1 Drive Dir*
1 Drive Dir*
CW Incr
2 MaxTravel*
100 deg
3 Travel*
100 deg
4 StepSize*
0.100%
5 Stall Time*
300 S
6 StallProt*
Enabled
7 LimitSwitch*
Accept
8 PositionUnit* deg
9 Temperature Unit*
9 Temperature Unit*
degF
4C
PositionSensrSetup
1 Set Pos 0%**
2 Set Pos 100%**
3 PresCPS V
1 Set Pos 0%**
2 Set Pos 100%**
3 PresCPS V
2.816 v
4 CPS Zero%*
1.000 v
5 CPS Span
4.000 v
6 CPS RngLwr
1.000 v
7 CPS RngUpr
5.000 v
8 Pos S/N*
454
9 Snsr Dir
CW Incr
4D
Demand Setup
1 DemRngLwr * 4.00
1 DemRngLwr * 4.00
mA
2 DemRngUpr * 20.00
mA
3 Dem Curve*
Linear
4 Dem Curve Spcl
5 LOS Mode*
5 LOS Mode*
Stay
6 LOS Pos*
50.00 %
7 DemLimLwr* 3.20
mA
8 DemLimUpr
22.00 mA
4E
Feedback Setup
1 FB RngLwr*
1 FB RngLwr*
4.00 mA
2 FB RngUpr*
20.00 mA
3 Feedback*
Enabled
4 FB Curve*
Linear
4F
Torque Setup
1 Trq/Thrust*
1 Trq/Thrust*
Enabled
2 Ovt Prot*
Enabled
3 ShutDwnTrq*
150
4 Trq Null*
163 TK
5 Trq Const*
279 TK
4G
Op Mode
Follow*
Hold*
RunCW*
RunCCW*
Stay
Stop*
Follow*
Hold*
RunCW*
RunCCW*
Stay
Stop*
4H
Status
1 LED Status
2 Operating Status
3 Switch Status
4 Local Cntrl Status
5 Line Freq
6 CW Inhibitors
7 CCW Inhibitors
1 LED Status
2 Operating Status
3 Switch Status
4 Local Cntrl Status
5 Line Freq
6 CW Inhibitors
7 CCW Inhibitors
4I
4J
CW Torque
1 Segment 1
1 Segment 1
0 %
2 Segment 2
12 %
•
•
•
Segment 10
66 %
4K
CCW Torque
1 Segment 1
1 Segment 1
5 %
2 Segment 2
6 %
•
•
•
Segment 10
62 %
4L
Alarm Setup
1 AlarmPol*
1 AlarmPol*
Drops Out
2 Alarm Mask*
4M
RealTimeClock
1 RTC Day*
1 RTC Day*
8
2 RTC Month*
1
3 RTC Year*
2006
4 Hour (24)*
8
5 Minute*
5
4A
Review
(3)
3B
Device Information
1 Tag*
1 Tag*
BECK2006
2 Descriptor*
3 Message*
4 Model#
3 Message*
4 Model#
11-159
5 Drive S/N*
6 Instld*
6 Instld*
23/05/2006
7 Setup*
23/05/2006
8 Calbrtd*
28/05/2006
9 Review
Poll
addr*
0
3C
3D
Statistics
1 Starts
1 Starts
485213
2 Reversals
242606
3 Stalls
0
4 OverTorques 14
5 Pk Torque
5 Pk Torque
127%
6 TotRunTm
53268 S
7 High Temp
155 degF
8 Low Temp
23 degF
3E
3F
Diagnostics
1 Status
2 Tests
3 CW Torque
4 CCW Torque
5 Alarm Setup
6 RealTimeClock
1 Status
2 Tests
3 CW Torque
4 CCW Torque
5 Alarm Setup
6 RealTimeClock
3G
Calibration Trim
1 PresCPS V*
1 PresCPS V*
2.816 v
2 Loop(Dem)*
11.29 mA
3 Feedback*
11.29 mA
4 Trq/Thrust*
3 %
5A
Dem Curve Spcl
1 DemNode1X 0
1 DemNode1X 0
%
2 DemNode1Y 0
%
3 DemNode2X 5
%
4 DemNode2Y 5
%
•
•
•
DemNode21X
100
%
DemNode21Y
100
%
5B
LED Status
Status OFF
Reverse
Status OFF
Reverse
OFF
Forward
OFF
Demand
OFF
Position
OFF
Trq/Thrust
OFF
Stall OFF
Temperature
Temperature
OFF
FB Open
OFF
Limit OFF
Acknowledge
Acknowledge
OFF
5C
Operating Status
Dem <> Limits
Dem <> Limits
OFF
Pos <> Limits
OFF
Temp <> Limits OFF
Torq <> Limits
Torq <> Limits
OFF
Over Torq Stop OFF
Stalled OFF
Feedback Open
Stalled OFF
Feedback Open
OFF
Switch Block
OFF
5D
Switch Status
LV Lim CCW
LV Lim CCW
OFF
LV Lim CW
OFF
OvrRd CCW
OFF
OvrRd CW
OFF
OvrRd Stop
OFF
HndSw CCW
OFF
HndSw CW
OFF
HndSw AUTO
OFF
5E
Local Cntrl Status
Calibrate
Calibrate
OFF
Set Pos 100%
OFF
Set Pos 0%
OFF
Set Dem 100%
OFF
Set Dem 0%
OFF
5F
CW Inhibitors
Balance
Balance
ON
Supervisory
OFF
Stall OFF
OverTrq/Thr
OverTrq/Thr
OFF
Switch Block
OFF
Bad Pos Sig
OFF
Bad Dem Sig
OFF
Local Cal
OFF
5G
CCW Inhibitors
Balance
Balance
ON
Supervisory
OFF
Stall OFF
OverTrq/Thr
OverTrq/Thr
OFF
Switch Block
OFF
Bad Pos Sig
OFF
Bad Dem Sig
OFF
Local Cal
OFF
5H
Alarm Mask
DemandLOS
DemandLOS
ON
Trq/Thrust High
ON
Stall ON
Trq/Thrust Stop
Trq/Thrust Stop
ON
Stop/Limit
ON
FeedbackLOS
ON
Temperature
ON
PositionLOS
ON
RTC Fail
ON
Torq/Thrust/MeasFail
PositionA/D Error
DemandMeasFail ON
Reserved 1
PositionA/D Error
DemandMeasFail ON
Reserved 1
ON
PositionLOS
ON
TemperatureMeasFail
MemoryFail
MemoryFail
ON
InvalButtonPress ON
DemandTooHigh ON
DemUnderHART/FF Ctl
DemandTooHigh ON
DemUnderHART/FF Ctl
ON
DemUnderPAT Ctl
ON
(3) PROVIDES AN EXTENDED LIST OF DRIVE PARAMETERS
Tests
1 FB Out Test**
2 Board Self-Test**
3 Identify Device**
4 Board Reset**
1 FB Out Test**
2 Board Self-Test**
3 Identify Device**
4 Board Reset**
Configuration
1 General Setup
2 PositionSensrSetup
3 Demand Setup
4 Feedback Setup
5 Torque Setup
6 Restore to Factory**
7 Use Default Setup**
1 General Setup
2 PositionSensrSetup
3 Demand Setup
4 Feedback Setup
5 Torque Setup
6 Restore to Factory**
7 Use Default Setup**
Manual Operation
1 Op Mode*
1 Op Mode*
Follow
2 Demand*
45.3%
3 Reset Stall**
Figure 1
BECK-MK2 HART COMMUNICATOR MENUS FOR THE DCM-2