Bunn LCA-2 LP 38791.0000K Manual Do Utilizador

Página de 26
12
PROGRAMMING THE DISPENSER
Open the dispenser door to access the digital programming module with LED display.
Two basic modes are available to the operator: Display Mode and Program Mode.
To enter the Display Mode, Set the RUN/NIGHT/PROGRAM Switch to the RUN position.
To enter the Program Mode, Set the RUN/NIGHT/PROGRAM Switch to the PROGRAM position.
Display Mode: Used to view the current set-up values. Use the MENU switch to scroll to the next display.
NOTE: The display blanks out after two minutes of inactivity. Press any button to activate the display.
 
LCD DISPLAY 
 DISPLAY MODE 
 DESCRIPTION
Home View
DisplaysTank Temperature.
Tank Temperature
Displays target Tank Temperature (F°)
Regular Dispense Ratio
Displays Left Dispense Ratio (XXX:1)
Decaf Dispense Ratio
Displays Right Dispense Ratio (XXX:1)
Cup Dispense Volume
Displays Cup Dispense Volume (XX.X 
Oz.). Set to 0.0 for “Push and Hold” 
Dispense Mode.
Carafe Dispense Volume
Displays Carafe Dispense Volume 
(XX.X Oz.)
38791 072307
MENU
(-)
(+)
1 8 0
MENU
(-)
(+)
0 1 1 8 0
MENU
(-)
(+)
0
3
0 2
MENU
(-)
(+)
0
3
0 3
MENU
(-)
(+)
0 4 0.0
MENU
(-)
(+)
0 5 0.0