Honeywell HMR4007 Manual Do Utilizador

Página de 8
HMR4007
SENSOR PRODUCTS 
SPECIFICATIONS
Characteristics
Conditions
Min
Typ
Max
Units
General
  Accuracy 
0.2
0.1
mm
  Resolution
0.1
mm
  Hysteresis
0.01
mm
  Repeatability
0.01
0.1
mm
  Update Rate 
10
30
Hz
  Standoff 
Distance (gap) between the target 
magnet and the sensor board
0.1
5
(note 1) 
mm
Magnetic Field
  Range 
magnetic field at the sensor array 
80
(note 1)
gauss
  length 
apparent magnet length at sensor array
23
(note 3) 
mm
  Orientation 
Axial
(note 2)
Electrical
  Input Voltage 
Unregulated
6
28
VDC
  Current 
15
20
mA
Digital Interface
  Baud Rate 
nonstandard synchronous serial interface
1000
21,000
Bits / sec. 
  Signaling Level
TTL levels 
( “1” ) 
( “0” ) 
3.5
-0.3
5.0
1.5
VDC
VDC
  Connector
In-Line 6-Pin Block (0.1” spacing)
Analog Interface
  Analog Output
D/A output 
0
2.5
VDC
  Update Rate 
10
30
Hz
  Signaling Level
TTL levels 
( “1” ) 
( “0” ) 
3.5
-0.3
5.0
1.5
VDC
VDC
  Connector
In-Line 4-Pin Block (0.1” spacing)
Physical
  Dimensions
Circuit Board Assembly
(including connectors)
40.0 x 80.0 x
12.0
mm
  Weight 
HMR4007
16.5
grams
Environment
  Temperature 
Operating
Storage
-40
-55
-
-
+70
+125
°C
Note 1: The standoff distance between the sensor board and the target magnet is highly variable. A magnet of sufficient strength,
however, must be used to maintain a magnetic field strength of 80 gauss (min.) at the sensor array and an apparent
magnet length of 23 mm.
Note 2: Sensor boards are factory calibrated in the axial mode using a 27mm cylindrical magnet. Operation in the radial mode
must be configured by the user.
Note 3: cf. "Magnet Considerations" (pg. 8)
Solid State Electronics Center 
www.magneticsensors.com
 (800) 323-8295
Page 3