30" Freestanding Gas Range
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
SF340BEH
SF341BEK
SF356BEK
SF357BEH
SF357BEK
SF357PEK
TGS325G
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.
CLOCK
8.8:88
TIMER
TIMER
29-7/8" width
46-7/8"
overall
height
25"
36"
cooktop
height
27-1/8" depth
with handle
*** Note: 30" min. when bottom of wood or metal cabinet
is protected by not less than 1/4" flame retardant
millboard covered with not less than No. 28 MSG
sheet steel, 0.015" stainless steel, 0.024" aluminum or
0.020" copper.
36" min. clearance between the top of the cooking
platform and the bottom of an unprotected wood or
metal cabinet.
Contact a qualified floor covering
installer to check that the floor
covering can withstand at least
200˚F.
Use an insulated pad or 1/4"
plywood under range if installing
range over carpeting.
For minimum
clearance to top of
cooktop, see Note.***
Do Not pinch the power supply cord
between the range and the wall.
Do Not seal the range to the side
cabinets.
2" min.
countertop
space to side
wall or other
combustible
material
This shaded area recommended
for installation of rigid gas pipe.
Flexible gas pipe and electrical
outlet are recommended in either
shaded area.
18" min.
clearance upper
cabinet to
countertop
13" max. upper
cabinet depth
If cabinet depth is greater than 24",
oven frame must extend beyond
cabinet fronts by 1/2" min.
30-1/8" opening
width
30" min. cabinet
opening width
8"
4-1/2"
4-1/2"
2"
2"
17"
17"
8"
Gas supply:
Use 3/4" rigid pipe gas supply line
to the range location. A smaller size pipe on long
runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be 1/2"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by AGA or CSA, 4-5 feet long, 
1/2-inch or 3/4-inch I.D., be used for connecting
the range to the rigid gas supply line. A 1/2" male
pipe thread is needed for connection to pressure
regulator female pipe threads. An individual
manual shutoff valve must be located in the same
room, but external to the range.
Electrical:
A 120-volt, 60-Hz, AC-only, 
10-ampere, electrical supply fused on both sides
of the line. A separate circuit is recommended. A
time-delay fuse or circuit breaker is recommended. 
Ref. 8273169 Rev. A