Whirlpool KR-28 Manual Do Utilizador

Página de 29
- 8 -
L1
N
BK
BK
R
W
IGNITION 
SWITCH
DIRECT SPARK 
IGNITION CONTROL
6
4 3 2 1
7
9
10
TOP BURNERS       GND
10-PIN CONNECTOR
J1
This 120 VAC is detected by the control, and
generates two sparks-per-second to all of the
top  burners.  Note  that  in  the  strip  circuit  be-
low,  120  VAC  is  present  at  the  control  at  all
times through input pin J1-10, and output pin
J1-4.
120 VAC is required to:
a) Monitor the internal self-diagnostics of
the control board.
b) Monitor the flame safety circuits to both
of the oven burners.
NOTE:  The  top  burners  are  operator-moni-
tored, and do not require electronic monitor-
ing.
COOKTOP BURNER OPERATION
The  top  burner  spark  ignition  system  is  initi-
ated when the burner control is turned to the
LITE position.
120 VAC is supplied through the ignition switch
from the L1 side of the circuit to the direct spark
ignition control at input J1-9 on the control. The
circuit is completed through output pin J1-4 to
the neutral side of the circuit.
ELECTRONIC SPARK IGNITION
Cooktop Strip Circuit