SERVICE (cont.)
Tank Heater
Location:
The tank heater is located in the tank lid.
Test Procedure:
1. Disconnect the dispenser from the power source.
2. Check the voltage across the terminals of the tank
heater with a voltmeter. Connect the dispenser to
the power source. The indication must be:
a.) 100 to 120 volts ac for 100 to 120 volt models
or
b.) 200 to 240 volts ac for 200 to 240 volt models
or
c.) 230 volts ac for 230 volt models.
3. Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, replace the tank
heater.
FIG. 16a TANK HEATER
FIG. 16c TANK HEATER WIRING
This
eq
uipm
ent
is to
be
ins
talle
d to
com
ply wi
th the
Bas
ic P
lum
bing
Co
de
of
the
Bui
lding
Of
ficia
ls a
nd
Cod
e
Adm
inistr
ators
Inte
rna
tion
al, In
c. (B
OC
A)
an
d th
e Food
Ser
vice
Sani
tation
Ma
nua
l
of th
e Food
and
Dr
ug
Adm
inistr
atio
n (F
DA
).
BLK to Limit
Thermostat
BLU to Control
Board Relay
P1780
P4093
4. Remove the tank heater from the tank lid and in-
spect it for cracks in the sheath.
If the sheath shows no sign of damage, proceed to #5.
If the sheath is damaged, replace the tank heater.
5. Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reinstall the tank
heater. The tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.
Removal and Replacement:
1. Remove the wires to the tank heater.
2. Remove the 8-32 nuts from the tank heater flange.
3. Remove the tank heater.
4. Inspect the tank heater gasket and replace if neces-
sary.
5. Securely install the new tank heater. Be certain of
a watertight seal.
6. Reconnect the wires, FIG. 10.
P1993
FIG. 16b TANK HEATER
42311 071310
1800W-120V
0
7.44 -
0
8.67
4000W-240V
13.43 - 15.51
4000W-208V
10.09 - 11.99
6000W-240V
0
8.85 - 10.23
6000W-208V
0
6.67 -
0
7.70
HEATER
RESISTANCE
TERMINAL TO SHEATH - INFINITE (OPEN)
H 10