Model HDS-200/300
4-1.  TROUBLESHOOTING GUIDE
Product not
Cold well or hot well not
• Check plugs under table-top
holding
plugged-in
on french fry end of HDS-300
temperature
Product held too long
• Only hold product for
recommended times
Cold well setting turned
• Turn control setting to about 6
Compressor overheated
• Clean condenser coil
Product not a proper
• Be sure product is at proper
temperature when placed
temperature
into unit
Defective fuse for refrigeration
• Replace 15 amp fuse
unit
Refrigeration unit runs
Frost build-up
• Defrost unit
constantly
Condensor coil dirty
• Clean condenser coil
Power switch on but
Open Circuit
• Plug unit in
no power to unit
• Check circuit breaker
• Check 15 amp fuses
• Check cord and plug
for loose connection
Not all lights
Faulty light bulbs
• Replace with new bulb,
on
per Light Bulb Replacement
Section
Lights will
Defective fuse
• Replace 15 amp fuse
not turn on
PROBLEM
CAUSE
CORRECTION