England's Stove Works 25-PDVC Instrução De Instalação

Página de 29
 
IMPORTANT!  READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING 
CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. 
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR 
DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS. 
9
     The through-the-wall installation is the least expensive and simplest installation.  In a 
through-the-wall installation you should be mindful of the snowdrift line, as well as dead 
grass and leaves.  We recommend a three foot (3’) minimum vertical rise on the inside or the 
outside of the dwelling. 
  
Through the Ceiling 
When venting the stove through the ceiling, the pipe is connected the same as through the wall, 
except the clean out tee is always on the inside of the house, and a 3” adapter is added before the 
clean-out tee.  You must use the proper ceiling support flanges and roof flashing supplied by the pipe 
manufacturer -- follow the pipe manufacturer’s directions and Illustration 1 in this manual. It is 
important to note that if your vertical runs of pipe are more than fifteen feet (15’), the pellet vent pipe 
should be increased to four inches (4”) in diameter. Do not exceed four feet (4’) of pipe on a 
horizontal run, and do attempt to use the least number of elbows in the flue system. If an offset is 
used it is better to install a 45-degree elbow whenever possible.  NOTE:  Installing elbows may inhibit 
your draft by up to 15% per elbow.
 
 
Existing Flue System 
     If you are replacing a wood stove with a pellet unit the chimney or pipe should be thoroughly 
cleaned before proceeding with the installation. If connecting this stove to a factory built chimney, it 
may ONLY be a 6” flue, UL103 HT venting system (ULC S629 if Canada).  Connection to any other 
factory built chimney may result in a poorly operating or dangerous stove installation.  When 
connecting to an existing masonry chimney, the cross-sectional area of the flue must be considered.  
A chimney with a flue larger than 6” round (28.27 sq. in.) may require relining with an approved pellet 
stove chimney lining system.  Make sure the chimney meets the minimum standards listed in NFPA 
211 (A chimney professional can confirm this upon inspection). 
 
Outside Air (Outside Combustion Air Intake) 
     Outside air is mandatory for this unit to operate properlyThis unit has been designed and tested 
with this connection, because so many homes are airtight and there is not adequate combustion air 
available inside the dwelling. The air intake pipe is located on the bottom side of the burn pot (from 
the rear) and measures 1 ½” inside diameter (I.D.). The connection can be made with a metal 1 
7
/
8
 ” 
I.D. coupler and pipe (see “Important Information” section of manual), and should exit through the 
wall.  Be sure to secure the pipe to the unit with a clamp or aluminum tape.  The outside end of the 
pipe should be covered (screened) to prevent foreign matter from entering the system.  
Our Outside 
Air Kit (Part Number PU-OAK) can be used.  
 If the unit is located below ground level, you will need to 
run the pipe up and then outside the dwelling.  NOTE:  If the total run of the connection exceeds 6’, if 
more than 2 elbows are used, or if a basement installation, use 3” metal pipe (and coupler) instead.  
Note:  If an older unit, measure the opening to determine what size pipe to use or couple to. 
 
Mobile Home Installation 
     Secure the heater to the floor using the two holes in the pedestal.  If the unit is on a combustible 
surface, you will need to drill matching holes in the floor protection that you choose (see Floor 
Protection section).  Do not disturb the structural integrity of the home, be sure the unit is 
permanently electrically grounded to the chassis of your home and remember that outside 
combustion air is mandatory.
 
 
 
 
 
 
 
 
IMPROPER INSTALLATION:    The manufacturer will not be held responsible for damage caused by the 
malfunction of a stove due to improper venting or installation. 
Call 800-245-6489 and/or consult a professional installer if you have any questions. 
IMPORTANT: 
Improper hook-up (too much pipe, too many elbows, etc.) will cause the unit not to operate.  
Call Technical Support (800-245-6489) if you have questions about your hook-up or if your unit will not 
operate. 
WARNING: DO NOT INSTALL IN SLEEPING ROOM 
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL AND 
CEILING/ROOF MUST BE MAINTAINED.