Grounding Requirements
This machine MUST be grounded. In the event of certain 
types of malfunctions or breakdowns, grounding provides 
a path of least resistance for electric current to travel—in 
order to reduce the risk of electric shock.
Improper connection of the equipment-grounding wire will 
increase the risk of electric shock. The wire with green 
insulation (with/without yellow stripes) is the equipment-
grounding wire. If repair or replacement of the power 
cord or plug is necessary, do not connect the equipment-
grounding wire to a live (current carrying) terminal.
 
Check with a qualified electrician or service personnel 
if you do not understand these grounding requirements, 
or if you are in doubt about whether the tool is 
properly grounded. If you ever notice that a cord or 
plug is damaged or worn, disconnect it from power, and 
immediately replace it with a new one.
Grounding Prong
Current Carrying Prongs
6-15 PLUG
GROUNDED
6-15 RECEPTACLE
Figure 8. NEMA 6-15 plug & receptacle.
For 240V Connection
The  machine  must  be  properly  set  up 
before  it  is  safe  to  operate.  DO  NOT 
connect  this  machine  to  the  power 
source  until  instructed  to  do  later  in 
this manual.
DO NOT modify the provided plug or use 
an  adapter  if  the  plug  will  not  fit  your 
receptacle.  Instead,  have  a  qualified 
electrician install the proper receptacle 
on a power supply circuit that meets the 
requirements for this machine.
Extension Cords
We do not recommend using an extension cord with this 
machine. Extension cords cause voltage drop, which may 
damage electrical components and shorten motor life. 
Voltage drop increases with longer extension cords and 
the gauge smaller gauge sizes (higher gauge numbers 
indicate smaller sizes).
Any extension cord used with this machine must contain a 
ground wire, match the required plug and receptacle, and 
meet the following requirements:
Minimum Gauge Size at 240V ...................... 14 AWG
Maximum Length (Shorter is Better) ................50 ft.
The power cord and plug specified under "Circuit 
Requirements for 240V" on the previous page has an 
equipment-grounding wire and a grounding prong. The 
plug must only inserted into a matching receptacle 
(outlet) that is properly installed and grounded in 
accordance with all local codes and ordinances (see 
Figure 8).