4. Remove the cap from the gas pressure regulator using a 
flat-blade screwdriver.
NOTE: Do not remove the spring beneath the cap.
5. Turn the cap over so that N or NAT is visible.
6. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners. 
2. Locate the Natural gas orifice spuds for top burners in the 
package containing literature included with the range. Two 
Natural gas spuds are stamped “149” and two “125.”
3. Remove the LP gas orifice spuds using a 7 mm combination 
wrench. 
4. Install the Natural gas orifice spuds using a 7 mm 
combination wrench. 
NOTE: This range is equipped with 2 standard burners and 
2 super burners. Spud size and location remain the same.
5. Place LP gas orifice spuds in the parts bag for future use and 
keep with the package containing literature.
6. Reinstall burners, burner caps and burner grates.
A. Cap
A. Cap
A. Burner cap
B. Burner
A
A
A
B
A. Spud
B. Holder
A
B
2 super 
burners. Spud size/location rem ain the sam e.
 
Standard
Burner 125
Super
Burner 149
Standard
Burner 125
Super
Burner 149