L## Master Arm Delay 
Default: 
Refer to the program record sheet 
Selection: 
- or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Master Arm 
Delay 
[COMMAND][1] 
Master arms areas based on the CC# Scope of the 
keypad using an exit delay time. 
When this item is accessed through the Function List, 
Master Arm All allows the user to arm all areas 
according to the authority level of the user and within 
the CC# Scope of the keypad using an exit delay 
time. 
Arm Area arms only the area displayed. If 
COMMAND 1 is used, it arms only the area where 
the keypad is assigned. 
L## Master Arm Instant
 
Default: 
Refer to the program record sheet 
Selection: 
- or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Master Arm 
Instant 
[COMMAND][1][1] 
This authority level permission allows a user to 
execute the Master Arm Instant function. Refer to 
Master Arm Instant on page 60. 
Arm Area arms only the area to which the keypad is 
assigned. 
If COMMAND 11 is used, it arms only the area where 
the keypad is assigned. 
 
Use COMMAND 11 carefully because all 
Perimeter and Interior points become 
Instant Armed. 
 
L## Perimeter Instant 
Default: 
Refer to the program record sheet 
Selection: 
- or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Perimeter Instant 
Arm 
[COMMAND][2] 
Instant arm all Perimeter points, including Delayed 
points, only in the area where the keypad is 
assigned. 
 
L## Perimeter Delay 
Default: 
Refer to the program record sheet 
Selection: 
- or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Perimeter Delay 
Arm 
[COMMAND][3] 
Delay arm all Perimeter Delay point responses only 
in the area where the keypad is assigned. 
L## Watch Mode 
Default: 
Refer to the program record sheet 
Selection: 
- or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
6 Watch 
Mode 
[COMMAND][6] 
Initiate the Watch Mode in the area to which this 
keypad is assigned. 
L## Perimeter Partial 
Default: 
Refer to the program record sheet 
Selection: 
- or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
Perimeter Partial 
Arm 
[COMMAND][8] 
Partially arms only the area where the keypad is 
assigned. 
 
This function ignores the A# Force 
Arm/Bypass Max
 entry in Area 
Parameters. 
 
 
Local Only Reporting:  No Closing 
Report is sent to the central station, but a 
Perimeter Delay Closing Event is 
generated in the event log. 
 
L## View Area Stat 
Default: 
Refer to the program record sheet 
Selection:  - or E 
 
Function 
No. 
Function Name 
Alternate 
Keystroke 
View Area Status  (Menu function 
only) 
View the current arm or disarm status and the not 
ready to arm status of all areas within the scope of 
the keypad in this area. The user needs arming and 