4. Install the Natural gas orifice spuds using a 7 mm 
combination wrench. 
NOTE: Depending on model, the range cooktop may be 
equipped with 4 standard burners, 3 standard burners and 
1 power burner, or 3 standard burners, 1 power burner and 
1 center burner. Spud size/location remain the same.
5. Place LP gas orifice spuds in the parts bag for future use and 
keep with the bag containing literature.
6. Reinstall burners, burner caps and burner grates.
To Convert Oven Burner
1. Open the oven door and remove oven racks, oven tray, flame 
spreader and set aside.
2. Lift oven burner. The orifice spud is behind the oven burner 
air shutter.
3. Locate Natural gas orifice spud stamped “47” in the bag 
containing literature supplied with the range.
4. Use a 7 mm combination wrench and remove the LP gas 
orifice spud.
5. Install the number “47” LP gas spud.
IMPORTANT: Do not over tighten.
6. Place LP gas oven burner spud in plastic parts bag along 
with LP gas cooktop burner spuds for future use and keep 
with the bag containing literature.
7. Reinstall oven burner.
8. Reinstall oven racks, oven tray and flame spreader.
Complete Conversion
1. Refer to the “Make Gas Connection” section for properly 
connecting the range to the gas supply.
2. Turn the manual shutoff valve in the gas supply line to the 
open position.
3. Refer to the “Electronic Ignition System” section for proper 
burner ingestion, operation and burner flame adjustments.
IMPORTANT: You may have to adjust the “LO” setting for 
each cooktop burner.
Checking for proper cooktop and oven burner flames is very 
important. The small inner cone should have a very distinct 
blue flame ¼" to ½" (0.64 cm to 0.13 cm) long. The outer 
cone is not as distinct as the inner cone. Natural gas flames 
do not have yellow tips.
4. Close the broiler door and press the CANCEL/OFF pad.
5. Refer to the “Complete Installation” section to complete this 
procedure.
A. Spud
B. Holder
A. Standard burner - Natural gas orifice spud number 125
B. Power burner - Natural gas orifice spud number 132
C. Center burner - Natural gas orifice spud number 128
D. Standard burner - Natural gas orifice spud number 125
E. Standard burner - Natural gas orifice spud number 125
A. Oven burner
B. Air shutter
A
B
A
B
C
D
E
B
A
A. Natural gas oven orifice spud stamped with “47”
A