3. Feed the power supply cord through the strain relief on the 
cord/conduit plate on bottom of range. Allow enough slack to 
easily attach the wiring to the terminal block.
4. Use Phillips screwdriver to connect the green ground wire 
from the power supply cord to the range with the ground-link 
screw. The ground wire must be attached first.
5. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the #10-32 hex nuts.
6. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with #10-32 hex nuts.
7. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power 
cord rated at 250 volts minimum, 40 amps or 50 amps that is 
marked for use with nominal 1
³⁄₈" (3.5 cm) diameter 
connection opening, with ring terminals and marked for use 
with ranges.
8. Replace terminal block access cover.
3-wire connection: Power Supply Cord
Use this method only if local codes permit connecting chassis 
ground conductor to neutral wire of power supply cord.
1. Feed the power supply cord through the strain relief on the 
cord/conduit plate on bottom of range. Allow enough slack to 
easily attach the wiring to the terminal block.
2. Use 
³⁄₈" nut driver to connect the neutral (white) wire to the 
center terminal block post with one of the #10-32 hex nuts.
3. Connect line 1 (black) and line 2 (red) wires to the outer 
terminal block posts with #10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, only use a power 
cord rated at 250 volts minimum, 40 amps or 50 amps that is 
marked for use with nominal 1
³⁄₈" (3.5 cm) diameter 
connection opening, with ring terminals and marked for use 
with ranges.
5. Replace terminal block access cover.
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires - large opening
E. Small opening
A. #10-32 hex nut
B. Ground-link screw
C. Line 1 (black)
D. Green ground wire
E. Neutral (center) wire 
F. Line 2 (red)
A
B
C
D
E
A
B
C
F
D
E
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Power supply cord wires - large opening
E. Small opening
A. #10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Neutral (white) wire
E. Line 2 (red)
A
B
C
D
E
A
B
C
D
E